12) OPERATING PARAMETER MANAGEMENT - DISPLAY
PARAMETER
DEFINITION
Opening speed [°/s]
01
Closing speed [°/s]
02
TCA [s]
03
Disabled hold time [s]
04
VISTA SW SXL:
Spring-operated
closing speed
05
VISTA SW MXL:
Wind protection with
door closed
Opening force and
06
Closing force
Acceleration and
07
Deceleration
Approach angle
08
Solenoid lock voltage
09
Solenoid lock type
10
Solenoid lock
management time
11
Opening delay after lock
release
Closing limit switch
12
pressure
Single/Master/Slave
13
Door locked closed with
14
motor and lock
Auxiliary input 1
15
configuration
32
- VISTA SW SXL - VISTA SW MXL
INSTALLATION MANUAL
MIN.
MAX.
DEFAULT
CUSTOM
20
70
60
 
10
40
20
 
0
60
0
 
5
60
5
 
1
9
5
 
0
9
0
 
1
9
5
 
5
30
30
 
10
40
20
 
0
1
0
 
0
6
0
 
0
9
2
 
0
9
5
 
0
2
0
 
0
3
3
 
0
12
0
 
Motor speed during opening
Motor speed during closing
Waiting time before automatic closing.
Waiting time before automatic closing using the disabled opening command
or in Low Energy mode
Spring-operated closing speed (1=minimum speed, 9=maximum speed)
Sets wind protection strength with door closed
(0=wind protection disabled, 9=max. wind protection)
Force exerted by leaf during opening and closing before obstacle alarm is
generated. (1=most sensitive; 9=least sensitive)
Acceleration and deceleration speed
Adjusts approach angle (closing is 1/2 of opening)
0 = 12Vdc solenoid lock output
1 = 24Vdc solenoid lock output
0 = Not used
1 = Pulse mode with relock when door closes again
2 = Standard magnetic (maglock)
N.B. Maglocks can be supplied only with 24V, set the "Solenoid lock
voltage" parameter to 24V.
3 = Fail-safe magnetic
4 = Motorized
5 = Pulse mode with relock when power is cut off
6 = maglock with activation delay while closing
N.B. Maglocks can be supplied only with 24V, set the "Solenoid lock
voltage" parameter to 24V.
The time depends on the solenoid lock type:
- Pulse mode with relock when door closes again 50-500 ms
- Magnetic & Fail-safe 200 to 2000 ms
- Motorized 500 to 5000 ms
- Pulse mode with relock when power is cut off 100-1000 ms
Force exerted by the leaf to allow lock to engage
0 = Single board
1 = Board connected as Master
2 = Board connected as Slave
0 = Disabled
1 = Enabled with "Internal radar" mode
2 = Enabled with "Standard radar" mode
3 = Enabled with "Internal radar" and "Standard radar" mode
0 = Input configured as Disabled opening
1 = Input configured as Emergency opening
2 = Input configured as Interlock door with priority
3 = Input configured as Interlock door without priority
4 = Input configured as Lock Release Feedback
5 = Input configured as Lock release
6 = Input configured as Single Command with Master/Slave operating mode
7 = Input configured as Standby. If activated, it sets the door to standby only
with the door in the closed position.
8 = Input configured as wake up from Standby. If activated, it restores
operation following a Standby
9 = Input configured as step-by-step command, meaning that with a pulse
the door opens and stays open, standing by for another pulse to close, again
with the use of Int. Radar or Ext. Radar
10 = input configured as Temporary Stand By. If activated, the door is in stand
by and therefore the closing movement is spring-loaded. If deactivated, the
door works normally.
11 = Input configured as manual operation. If active, the operation of the
selector in the head is disabled.
12 = Input configured as Stop Closed operation. If active, the operation of the
selector in the head is disabled.