PARAMETER
DEFINITION
AUX-IN 2 input polarity
29
AUX-OUT 1 input
30
polarity
AUX-OUT 2 input
31
polarity
Force during reset
32
Opening angle
reduction percentage
33
level [%]
Assembly on lintel or on
34
door leaf
Disabled opening
35
Battery operation (Logic
active only with Vista
36
SW SXL)
ADAR INT configuration
37
Test
TS
Default
SD
Autoset
LP
Acquisition of
LS
supervised sensors
13 ) DOOR OPERATING MODE (With VISTA SEL or logic selection switch) Fig. O
EXTERNAL RADAR: Only the RADAR EXT input on the control circuit board is
monitored.
A signal from a sensor connected to this input causes the door leaf to open and
consequently close.
The solenoid lock, where fitted, locks the door leaf whenever it reaches the fully
closed position.
INTERNAL RADAR: Only the RADAR INT input on the control circuit board is
monitored.
A signal from a sensor connected to this input causes the door leaf to open and
consequently close.
The solenoid lock, where fitted, locks the door leaf whenever it reaches the fully
closed position.
RADAR IN STANDARD MODE: Both RADAR EXT and RADAR INT inputs on the
control circuit board are monitored. A signal from a sensor connected to one of
these inputs causes the door leaf to open and consequently close.
The solenoid lock, where fitted, locks the door leaf whenever it reaches the fully
closed position.
34
- VISTA SW SXL - VISTA SW MXL
INSTALLATION MANUAL
MIN.
MAX.
DEFAULT
CUSTOM
0
1
0
 
0
1
0
 
0
1
0
 
0
9
5
 
0
50
0
 
0
2
0
 
0
1
0
0
2
0
1
2
0
0
2
0
 
 
 
 
/
 
 
 
/
0 = N.O. Normally open
1 = N.C. Normally closed
0 = N.O. Normally open
1 = N.C. Normally closed
0 = N.O. Normally open
1 = N.C. Normally closed
Adjusts motor force at time for first operation following reset (0 = least force,
9 = most force)
During normal operation, swing will be smaller than the angle detected
during the stops acquisition procedure so as to allow operation when there is
no mechanical stop.
0 = Motor installed on lintel
1 = Motor installed on door leaf
2 = not available
0 = the speed of movement with "disabled" opening control is reduced
1 = the speed of movement with "disabled" opening control is equal to
parameters 01 and 02
0 = standard operation
1 = continuous operation
2 = panic operation
0 = as described page 11
1 = DDA active only with switch I 0 II -Fig.O- in logic 1
2 = DDA active on all logics
0 = Normal operation
1 = Cyclic testing, automatic opening and closing
2 = Intensive cyclic testing, automatic opening and closing
Restores all parameters to default values and resets the acquired travel.
Procedure:
1-Select command with [+] and [-] keys;
2-Press [ENT];
3-When display reads [--], hold [ENT] down for 5 seconds to validate;
4-When [--] disappears, release the [ENT] key
Travel acquisition.
Procedure:
1-Select command with [+] and [-] keys;
2-Press [ENT];
3-When display reads [--], hold [ENT] down for 5 seconds to validate;
4-When [--] disappears, release the [ENT] key.
Acquisition of connected supervised sensors.
Procedure:
1-Select command with [+] and [-] keys;
2-Press [ENT];
3-When display reads [--], hold [ENT] down for 5 seconds to validate;
4-When [--] disappears, release the [ENT] key.
5-When acquisition is done, confirm sensors detected with [ENT] or press
[ESC] to cancel.
DOOR CLOSED BY DAY: The door is locked in closed state. Panic feature, if
enabled, is on.
The automatic door operator commands the door leaf to close fully. With this logic
selected, the RADAR EXT and RADAR INT inputs on the control circuit board are
not monitored; the solenoid lock, where fitted, locks the door leaf.
DOOR CLOSED AT NIGHT: The door is locked in closed state. Panic feature, if
enabled, is off.
The automatic door operator commands the door leaf to close fully. With this logic
selected, the RADAR EXT and RADAR INT inputs on the control circuit board are
not monitored; the solenoid lock, where fitted, locks the door leaf.
DOOR TOTAL OPEN: The door is locked in open state.The automatic door operator
commands the door leaf to open fully. With this logic selected, the RADAR EXT
and RADAR INT inputs on the control circuit board are not monitored;
MANUALLY OPENED DOOR: With this logic selected, the RADAR EXT and RADAR
INT inputs are disabled. The door is opened and closed manually. The opening
safety sensor and closing safety sensor are only active in the event of motor-
driven opening for the disabl
DESCRIPTION