GAS PRESSURE (ALL MODELS): Natural Gas, Town Gas or LP {Liquid Propane Gas}
The gas pressure must be set at 4" W.C. (Water Column) (0.8 kPa) for natural gas and 10" W.C. (2.75 kPa) for
gas. If incoming pressure exceeds ½ PSI (3.45 kPa), an additional pressure regulator must be installed.
{Meeting this requirement is the owner's responsibility} The name plate indicates which form of gas fuel
supply is to be connected to this fryer LP or Natural Gas
All gas piping should be performed by a licensed plumber and approved by an authorized local building code
and fire protection inspector.

TESTING THE GAS SUPPLY PIPING CONNECTION

 When test pressures exceed ½ PSI (3.45 kPa), the fryer and its individual shutoff valve must be
disconnected from the gas supply piping system.
 When test pressures are ½ PSI (3.45 kPa) or less, the fryer must be isolated from the gas supply piping
system by closing its individual shutoff valve.
If any leaks must be repaired, ensure the line is free of any residual gas and then execute the needed remedial
action safely and properly to conform the prevailing codes and ordinances.
MOBILE FRYER INSTALLATION
Approved casters, the quick disconnect supply hose and a secure restraining device aren't/may
not be supplied with these fryers. A provided set of leveling legs is typical which allows a
stationery safe hook-up with the connection of proper gas piping.
Separate instructions for installing casters are included with each purchased caster kit/set:
 The installation must be made with a connector that complies with the current Standard for
Connectors for Movable Gas Appliances, ANSI Z-21.69 or Connectors for Moveable Gas Appliances,
CAN/CGA-6.16, and a quick-disconnect device that complies with the Standard for Quick-Disconnect
Devices for Use with Gas Fuel, ANSI Z-21.41 or Quick-Disconnect Devices for Use with Gas Fuel, CANI-
6.9.
 When installing a quick disconnect you must also install a means for limiting the movement of the
fryer. This restraining device prevents the gas line or quick disconnect hose from being strained. The
restraining device should be attached to the mounting system/cutout on the fryer's back panel. {See
illustration for location}
 The manufacturer/distributor offers an approved and proven mobile gas appliance installation kit
consisting or proper strength and size casters (2 with brakes), approved quick disconnect hose and
rated restraining cable. Its use maintains the factory equipment warranty – other set ups may result in
that protection being voided