1. Close the drain valve.
2. Fill the fryer tank with liquid shortening.
3. Shortening level should be between the min and max lines in the fryer tank.
4. Shortening will expand when heated. Do not fill the fryer tank (vat or pot) past the MAX line. Add
fresh shortening as needed to maintain oil level. DO NOT fill above the maximum fill fine embossed
into the fry vat. If no portion of a tube burner is exposed to air, solid shortening may be added
directly into the fryer, a little at a time to avoid any scorching or shortening of the oil life.

LIGHTING THE PILOT

1. Open the door.
2. Turn the thermostat OFF (see figure, view A). The thermostat is located behind the door.
3. Push the gas control valve knob and turn to OFF. Wait 5 minutes to vent unburned gas.
4. Push and turn gas control valve knob to the "L" in PILOT (see figure below, view B).
5. While still holding the knob in, light the pilot with a suitable flame. Continue to depress the knob until
pilot stays lit when knob is released. If the pilot doesn't remain lit, repeat steps 3 through 5.
6. Depress and turn gas control knob to ON (See figure below, view C).
7. If gas supply is interrupted, repeat steps 2 through 6.
A lit pilot is needed for proper fryer operation. The pilot is tested at the factory prior to shipping.