Mimic panel
to turn on and off (hold down for 2") and to exit from the menu during programming
to access the menu during programming
to increase the various settings
to decrease the various settings
(pellet loading/reserve button)
press once to 'inform' the boiler-fi replace memory that a 15 kg sack of pellets has been loaded, thereby allowing it to
keep track of the reserve.
(boiler setting button)
Controls a secondary circuit, e.g. that of a boiler. The right side of the display shows the temperature of any external
storage tank/boiler (if the boiler sensor is connected). Press the 'boiler' button to see the set value. If the boiler sensor
is not connected, dashes will appear instead of the temperature (--- °C).
Left display
Filling the feed screw
If the pellet storage tank is completely emptied, it follows
that the Archimedes' screw is also emptied. Before restarting
the stove you must fi ll it by following these steps: press the
+/- keys simultaneously (via the remote control or the synoptic
panel) for a few seconds, after which, having released the keys,
the display will show the text "Reload".
It is quite normal for some pellet residue to remain inside the
hopper, this is what the feed screw is unable to pick up. Once a
month, fully vacuum the hopper to prevent dusty residue from
accumulating.
Automatic ignition
With the boiler-fi replace on stand-by, press the 0/1 button for
2 seconds (on the synoptic panel or remote control). This will
start-up the ignition process, 'Start' will appear on the display
and a countdown will commence in seconds (1020). There
is no preset time for the ignition process: its duration will be
automatically shortened if the control board detects that certain
tests have been carried out positively.
The fl ame appears after about 5 minutes.
Manual ignition (in case of start up failure)
At a temperature lower than 3 °C – too low for the electrical
resistance to become red hot - or if the resistance is tempora-
rily not working, you can use a fi relighter to ignite the boiler-
fi replace.
INSTRUCTIONS FOR USE
Pellet load/reserve
Remote control receiver
Boiler
Insert a well-lit fi relighter into the combustion chamber, close
the door and press 0/1 on the synoptic panel or remote control.
Operating modes
Operating from synoptic panel/remote control.
With the boiler-fi replace running or on stand-by, from the
synoptic panel.
Press the + or – keys to increase or decrease the desired water
temperature.
It is possible to visualise (if the boiler probe is connected) the
temperature of any boiler/external storage, by pressing the
"boiler" key the set value is displayed, by pressing the +/- keys
while viewing the boiler value set that setting can be varied. If
the boiler probe is not connected dashes appear in place of the
temperature (--.-° C).