Rated power
Water heating power
Approx. overall effi ciency
Approx. water effi ciency
CO emission (13% O2)
Max. pressure
Operating pressure
Smoke output temperature from test EN14785
Minimum draught
Min./max. autonomy
Fuel consumption min./max.
Hopper capacity
Heating capacity *
Weight including packing
Diameter of smoke extract duct male thread
Air intake duct diameter (male)
* The heatable room dimensions are calculated on the basis of pellets with an lhv of at least 4300 kcal/kg and home insulation in
compliance with Italian law 10/91, and subsequent changes together with an expected heat output of 33 Kcal/m³ per hour.
* It is also important to consider the position of the boiler-fi replace in the room to be heated.
N.B.
1) Bear in mind that external devices may cause interference.
2) Warning: work on live components, maintenance and /or checks must be performed by qualifi ed personnel.
(Before carrying out any maintenance, disconnect the device from the mains power supply)
Power supply
Average power consumption
Power consumption during ignition
Remote control frequency
Protection on mains power supply
Protection on electronic circuit board
The data shown above is purely indicative.
EDILKAMIN s.p.a. reserves the right to make changes to these products to improve their performance with no prior
warning.
FEATURES
TECHNICALAND HEATING SPECIFICATIONS

ELECTRICAL CHARACTERISTICS

150
400
- 26
15,7
12,6
92,2
81
0,014
2
1,5
130
12
7,5 / 27
1 / 3,5
30
405
201
80
40
230Vac +/- 10% 50 Hz
infrared
Fuse 2AT, 250 Vac 5x20
Fuse 2AT, 250 Vac 5x20
-
kW
kW
%
%
%
bar
bar
°C
Pa
hores
kg/h
kg
kg
mm
mm
W