Les langues disponibles

112 | Specifications
Electrical data
output (grid)
Voltage range
Rated grid voltage
Maximum output
current (Iacmax)
Maximum AC output
error current
Measured power
Max. apparent power
Frequency area
Power factor (cos φ)
Compatible grid
types
Design of AC
connection
Maximum excess
current protection at
the AC output
AC output alternating
current (switch-on
current)
Supply type
Stand-by/night
power consumption
Topology
Conversion efficiency
Max. efficiency factor
EU efficiency factor
Bosch BPT-S 3 / 3.68 / 4 / 4.6 | Operating manual
BPT-S 3
BPT-S 3.68
184 to 265 V
184 to 265 V
230 V
230 V
13.0 A
16.0 A
100 A for 1 s
100 A for 1 s
3.0 kW
3.68 kW
3.0 kVA
3.68 kVA
45 to 55 Hz
45 to 55 Hz
0.9 inductive to 0.9 capacitive
TN Network / TT
TN Network / TT
Network
Network
AC plug
AC plug
20 A
20 A
0 A
0 A
Single phase
Single phase
approx. 1 W
approx. 1 W
transformerless
BPT-S 3
BPT-S 3.68
97 %
97 %
96.2 %
96.3 %
BPT-S 4
BPT-S 4.6
184 to 265 V
184 to 265 V
230 V
230 V
17.4 A
20.0 A
100 A for 1 s
100 A for 1 s
4.0 kW
4.6 kW
4.0 kVA
4.6 kVA
45 to 55 Hz
45 to 55 Hz
TN Network / TT
TN Network / TT
Network
Network
AC plug
AC plug
25 A
25 A
0 A
0 A
Single phase
Single phase
approx. 1 W
approx. 1 W
BPT-S 4
BPT-S 4.6
97 %
97 %
96.5 %
96.5 %