2. To confirm: Carry out a long gesture
■
Entry is confirmed: Flashing stops and the next menu
is displayed.
6.4.4
Setting the standard
If various standards apply in the selected country, the
Standard menu is displayed.
▶
Procedure
1. Carry out short gestures until the desired standard
appears (e.g. AR4105<13.8) and the angled
brackets flash:
Standard
<AR4105 <13.8>
2. Carry out a long gesture
■
The data (language, country, grid standard) is
transferred to the device:
When the data is being transferred, white LEDs light
up permanently.
Once the data has been transferred, the LEDs light
up in a blue circular pattern for three seconds.
The configuration is now complete.
6.5
Starting up the string inverter using
e.Data
Materials required
Ethernet cable with the following characteristics:
– Cable category CAT.5e or better
– Shielded FTP cable (Foiled Twisted Pair)
– UV-resistant
– Temperature-resistant: -20°C to +60°C
– Shielding up to the tip of the plug
Bosch BPT-S 3 / 3.68 / 4 / 4.6 | Operating manual