Electrical Installation; Connecting The Earthing Set - Bosch BPT-S 3 Manuel De Service

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

60 | Installation
WARNING
Bosch BPT-S 3 / 3.68 / 4 / 4.6 | Operating manual
5.1

Electrical installation

Risk of injury due to failure to follow the correct
sequence
Failure to connect the protective earth first before
assembling and installing the device can result in
serious injury or death.
First connect the protective earth (if necessary
through mains cable), then connect the solar
generator cable
Observe the order specified
Observe the safety instructions
5.1.1

Connecting the earthing set

Materials required
Rigid cable (copper cable 10 mm
cable 16 mm
Earthing set comprising:
– Terminal plate
– Detent edged washer
– Flat-head screw M6
An additional earth connection (irrespective of the
national regulations) is absolutely necessary: See the
earthing set in the scope of supply
Procedure
1. Take the terminal plate, detent edged washer, M6
flat-head screw from the accessories bag
2. Strip the rigid cable to 38 mm
3. Insert the screw and detent edged washer through
the U-plate (toothing of the detent edged washer
must be facing the terminal plate)
2
) not included in scope of delivery
English
2
or aluminium
Bosch Power Tec GmbH

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Bpt-s 4.6

Table des Matières