display of the programmed set-points on the display; of the water
in/out temperatures on the display; of the condensation and evapora-
tion pressures; of the electrical voltage values in the three phases of
the electrical circuit that powers the unit; of the alarms on the display;
of operation of the chiller or heat pump by means of display (THAETY-
THAESY-THAEQY);
user interface menu;
automatic pump operating time balance (DP1-DP2, ASDP1-
ASDP2, DPR1-DPR2 set ups);
automatic activation of standby pump in the event of an alarm
(DP1-DP2, ASDP1- ASDP2, DPR1-DPR2 installations);
recovery unit/desuperheater water intake temperature;
alarm code and description;
alarms log management (menu protected by manufacturer password).
In particular, for every alarm, the following are memorised:
date and time of intervention;
in/out water temperature values as soon as the alarm was trig-
gered;
the evaporation and condensation pressure values at the time of
the alarm.
alarm delay time from the switch-on of the connected device;
compressor status at the time of the alarm;
Advanced functions:
Hi-Pressure Prevent function with forced cooling capacity partiali-
sation for a high outdoor temperature (in summer mode);
set up for serial connection (SS, FTT10, KBE, KBM, KUSB acces-
sory);
possibility of having a discrete input for double set-point remote
management (DSP);
possibility of having a discrete input for total recovery management
(RC100), the desuperheater (DS) or for the production of domestic hot
water by means of a 3-way diverter valve (VDEV). In this case, there
is the possibility of using a temperature probe instead of the discrete
possibility of having an analogue input for the shifting set-point via
a 4-20mA remote signal (CS);
management of time bands and operating parameters with the
possibility of daily/weekly operating programs;
computer-assisted machine testing;
self-diagnosis with continuous monitoring of the machine operating
status.
MASTER/SLAVE management logic integrated into the single
units (SIR - Rhoss Integrated Sequencer) -
Explanation
Set-point regulation via the AdaptiveFunction Plus with two op-
tions:
Precision option);
set-point slidinge (Economy options).
Section II :: Installation and maintenance
58

SPARE PARTS AND ACCESSORIES

IMPORTANT!
Only Use original spare parts and accessories. RHOSS S.p.a. shall not be held
liable for damage caused by tampering with or work carried out by unauthorised
personnel or malfunctions caused by the use of non-original spare parts or ac-
cessories.

Factory Fitted Accessories

P1
Installation with pump
PR1
Installation with a pump on the RC100 recovery circuit
P2
Installation with increased static pressure pump
PR2
Installation with an increased head pump on the RC100
recovery circuit
DP1
Installation with double pump, including an automatically
activated pump in stand-by
DPR1
Installation with a double pump, including one automati-
cally activated in standby on the RC100 recovery circuit
DP2
Installation with increased static pressure double pump,
including an automatically activated pump in stand-by
DPR2
Installation with increased head double pump, including
an automatically activated pump in standby on the RC100
recovery circuit
ASP1
Installation with pump and storage tank
ASDP1 Installation with double pump, including an automatically
activated pump in standby and storage tank
ASP2
Installation with an increased head pump and storage tank
ASDP2 Installation with and increased head double pump, including
an automatically activated pump in standby and storage tank
STE
Shell and tube evaporator (T,S,Q versions)
CAC
Compressor aphonic ear muffs
BCI
(check the table)
BCI60
Soundproofed compressor box with high acoustic imped-
INS
(standard in the S version)
INS60
acoustic impedance material (standard in the Q version)
RS
DS
Desuperheater. Also active during winter operation for
THAEY
RC100
Heat recovery unit with 100% recovery. Active in summer
for more details
FI10
Modulating condensation control for continuous operation
as chiller up to -10°C of outdoor air temperature (standard
versions S-Q)
FI15
Modulating condensation control with fans with EC motor
(Brushless) for continuous operation as a chiller up to
-15°C outdoor air temperature
FIAP
Condensing control with over-pressured fans with EC mo-
tor (Brushless) and available static head according to the
following table:
Available static head
Single fan absorption
Average increase in noise of the
unit
(TCAEBY-TCAETY-THAETY)
Up to 130 Pa
Max 1.25 kW
2 dBA