ModelTHAESY
EER
ESEER +
ESEER EN 14511:2013
COP
Scroll/step compressor
Circuits
Fans
Heat exchanger
Amount of R410A refrigerant
Electrical data
Pump absorbed power (P1/ASP1) / (P2/ASP2)
Pump absorbed current (P1/ASP1) / (P2/ASP2)
Dimensions
Height (a)
Width (b)
Length (c)
Heat exchanger inlet/outlet connections and RC100
DS inlet/outlet connections
Weight
(*) Under the following conditions: condenser
inlet air temperature 35°C; chilled water
temperature 7°C; temperature differential
at evaporator 5 K; evaporator scaling factor
equal to 0.35x10-4 m2 K/W.
(**) In the following conditions: Evaporator
inlet water temperature 7°C B.S., 6°C B.U.;
hot water temperature 45°C; temperature dif-
ferential at condenser 5 K; fouling factor equal
to 0.35x10-4 m2 K/W.
(***) Sound pressure level in dB(A) referring to
refers to the units without the electric pump
Enclosed documents
269
kW
66,5
2,90
4,97
kW
66,2
2,85
4,24
kW
70,5
3,36
kW
70,8
3,32
dB(A)
46
dB(A)
78
2/3
1
n° x kW
2 x 0,48
3 x 0,48
m³/h
16900
m³/h
11,4
kPa
28
kPa
155
kPa
214
kPa
149
kPa
208
l
230
kW
88,0
m³/h/kPa 15,1 / 52
kW
17,0
m³/h/kPa
1,5 / 5
Kg
27
Kg
5,3
269
kW
22,9
kW
21,0
kW
1,1 / 2,2
1,1 / 2,2
V-ph-Hz
V-ph-Hz
A
38,0
A
48,3
A
197,3
A
126,9
A
2,4 / 4,5
2,4 / 4,5
269
mm
1700
mm
1210
mm
3250
Ø
2" Vic.
Ø
1"
Vic. 1"
1/4
Kg
930
(****) Sound power level in dB(A) on the basis of
measurements taken in accordance with UNI EN-
data refers to the units without the electric pump
(±)
referring to the unit operating with chilled water
temperature 7°C, differential temperature due
to evaporation of 5 K, hot water temperature
produced equivalent to 40/45°C (RC100) 50/60°C
(DS). NB. With heat pumps operating in winter
able is decreased from the portion supplied to the
desuperheater.
242
279
289
296
75,0
86,0
90,0
2,96
2,90
2,85
4,86
4,94
4,87
74,7
85,7
89,6
2,91
2,85
2,8
4,11
4,18
4,13
80,0
90,0
97,5
3,40
3,34
3,33
80,4
90,4
98
3,36
3,31
3,29
47
47
47
79
79
79
2/3
2/3
2/3
1
1
1
3 x 0,48
3 x 0,48
23900
23900
23400
12,9
14,8
15,5
31
27
31
144
113
109
212
188
185
136
103
97
204
178
173
230
230
230
99,0
113,0
123,0
17 / 53
19,4 / 51 21,2 / 56 24,2 / 58
19,0
22,0
24,0
1,6 / 5
1,9 / 6
2,1 / 5
27
28
35
5,3
5,3
5,3
279
289
296
25,3
29,7
31,6
23,5
26,9
29,3
1,5 / 3,0
1,5 / 3,0
400 – 3+N – 50
230 – 1 – 50 / 24 – 1 – 50
42,0
49,3
52,5
54,8
63,4
67,4
203,8
239,8
243,8
133,4
155,0
159,0
3,2 / 6,3
3,2 / 6,3
279
289
296
1700
1700
1700
1210
1210
1210
3250
3250
3250
2" Vic.
2" Vic.
2" Vic.
Vic. 1"
Vic. 1"
Vic. 1"
1/4
1/4
1/4
945
950
995
( ) Absorbed current/absorbed power value without
electric pump.
operating conditions.
(°) Data calculated in accordance with EN 14511:2011
under nominal conditions.
Refer to the serial number plate.
-
2112
2125
2146
105,0
119,5
137,5
2,85
2,93
2,91
4,96
4,79
4,90
104,6
119
136,9
2,8
2,88
2,86
4,21
4,09
4,17
114,5
128,5
147,0
3,33
3,30
3,30
115
129,1
147,6
3,3
3,27
3,27
49
50
50
81
82
82
2/3
2/3
2/3
1
1
1
4 x 0,48
6 x 0,48
6 x 0,48
31800
42700
41000
18,1
20,5
23,6
31
33
36
107
103
95
186
184
178
103
97
88
181
178
171
440
440
440
141,0
157,0
182,0
27 / 57
31,3 / 64
27,0
31,0
35,0
2,3 / 6
2,7 / 6
3,0 / 6
34
35
44
7,8
7,8
7,8
2112
2125
2146
36,8
40,8
47,3
34,4
38,9
44,5
1,5 / 3,0
1,5 / 3,0
1,5 / 3,0
61,1
67,8
78,6
81,4
93,2
106,2
243,4
269,6
332,2
159,4
184,8
217,4
3,2 / 6,3
3,2 / 6,3
3,2 / 6,3
2112
2125
2146
2000
2000
2000
1520
1520
1520
3450
3450
3450
2"
Vic.
2"
Vic.
2"
Vic.
1/2
1/2
1/2
Vic. 1"
Vic. 1"
Vic.
1/4
1/4
1/4
1260
1300
1375