2° GROUP
1° GROUP
Keys
(time OFF)
(time ON)
2 minutes
4 minutes
8 minutes
16 minutes
LEVELLING PUMP ACTIVATION
• Access the programming of the first group
according to the relative procedure.
• Press the second unit continuous
key (the key will light up).
• Press the second unit 1 small coffee
key.
NOTA: If the I small coffee
the pump will start up during the level.
If the 1 small coffee
up, the pump will not start up during the
level.
• Press the second unit continuous
key.
In this way the selected pump setting is sto-
red.
• To exit the programming, press the first unit
continuous
key.
NOTE: The settings will be saved even when
exiting the first unit programming
directly.
ADJUSTING KEYBOARD LIGHTING
INTENSITY
5 minutes
• Access the programming of the first group
10 minutes
according to the relative procedure.
20 minutes
• Press the second unit continuous
delivery key.
40 minutes
• The second unit 2 long coffees
very key will flash on and off.
• Press the key more than once to vary the
light intensity.
NOTE: You can set a maximum of five different
degrees of light intensity.
• To store the set light intensity values in the
memory, press the second unit continuous
delivery key.
key is lit up,
• To exit the programming, press the first unit
continuous delivery key
key is not lit
NOTE: The settings will be saved even when
exiting the first unit programming
directly.
STEAM NOZZLE WITH TEMPERATU-
RE PROBE (OPTIONAL)
• Make sure the temperature probe is con-
nected to the control unit.
• The temperature value can be planned by
sampling or manually depending by the
types of memorization planned in the para-
meter setting section and value goes from a
deli-
minimum of 50°C to a maximum of 95°C.
• By pressing the
group is possible to chose if you wont set
the steam temperature value manually or by
sampling.
• When you enter in this part of the menu, the
key of the second group is switched
on.
• By pressing the key
group , it is possible to change the way in
which settings are stored to memory.
.
• Press the continuous delivery key
the 2nd unit to memorise the temperature
value input mode.
Sampling:
• After entering in the program of the first
group, put a jag with milk under the steam
wand and press the
very of steam will start.
• By pressing again the
reached the maximum temperature, the control
board memorizes the temperature reached.
key of the second
of the second
for
key, the deli-
key, or if it is