Input Led
Parameter
Maintenance
L7
notification
L8
Fault log list
Note: "
" represents factory settings
All parameters can be adjusted as required without any contraindications, only the "Motor force on opening" and "Motor force in closing"
may require special attention:
• Use of high force values are not recommended to compensate for the fact that the leaf has anomalous points of friction; excessive force
may impair the safety system and damage the leaf.
• If the "Motor force control" is used in support of the system for impact force reduction, after each adjustment the force measure-ment pro-
cedure must be performed, as envisaged by standard EN 12445.
• Wear and atmospheric conditions influence movement of the gate; and force settings should be checked periodically.

10.4) Level 2 programming

By default the settable parameters are set as shown in Table 4 with: "
during modification procedures, as there is a maximum time interval of 10 seconds between pressing one key and another; otherwise the
system exits the procedure automatically memorising the changes made up to that time.
1.
Press and hold [Set] for approx. 3s
2.
Release [Set] when led L1 starts flashing.
3.
Press keys [▲] or [▼] to move the flashing led to the "in-put led" associated with the parameter to be modified
4.
Press and hold [Set] during steps 5 and 6
5.
Wait approx. 3s after which the led associated with the current level of the parameter to be modified will light up.
6.
Press keys [▲] or [▼] to move the led associated with the parameter value
7.
Release [Set]
Wait 10s to exit the programming mode automatically after the maximum time interval.
Note: points 3 to 7 can be repeated during the same programming phase to modify other parameters.

11) Maintenance notification

SOON enables the user to be notified when a maintenance
check needs to be performed on the automation. The num-
ber of manoeuvres after which the signal can be enabled is
selectable from 8 levels, by means of the modifiable para-
meter "Maintenance notifica-tion" (see Table 4).
Adjustment level 1 is "automatic" and takes into account manoeuvre
stress, i.e. force and duration of the manoeuvre, while the other adjust-
ments are set on the basis on the number of manoeuvres.
Table 5: maintenance notification signal with Flash and maintenance indicator
Number of manoeuvres
Less than 80% of the limit
Between 81 and 100% of the limit
Over 100% of the limit
14
Led (level)
L1
Automatic (based on gravity of manoeuvre)
L2
1.000
L3
2.000
L4
4.000
L5
6.000
L6
8.000
L7
10.000
L8
12.000
L1
Result of 1
st
manoeuvre (most recent)
L2
Result of 2
nd
manoeuvre
L3
Result of 3
rd
manoeuvre
L4
Result of 4
th
manoeuvre
L5
Result of 5
th
manoeuvre
L6
Result of 6
th
manoeuvre
L7
Result of 7
th
manoeuvre
L8
Result of 8
th
manoeuvre
Signal on Flash
Normal (0.5s on, 0.5s off)
At the start of the manoeuvre, remains lit for 2s then
proceeds normally
At the start of the manoeuvre, remains lit for 2s then
proceeds normally
Value
" but can be modified at any time as described below. Take care
The maintenance requirement notification is via the flashing light or the
maintenance indicator, depending on the relative settings (see Table 4).
On the basis of the number of manoeuvres performed with respect to the
programmed limit, the Flash flashing light and maintenance indicator acti-
vate the signals as described in Table 5.
Signal on maintenance indicator
On for 2s at the start of opening
Flashes throughout manoeuvre
Flashes continuously.
Description
Controls the number of
manoeuvres after which the
automation maintenance
notification signal is sent
(see paragraph "13 Mainte-
nance notification").
Enables the user to check
the type of faults occurring
in the last 8 manoeuvres
(see paragraph "14 Fault
log list").