Check Of Number Of Manoeuvres Performed; Manoeuvre Counter Reset; Fault Log List; Connecting Other Devices - Nice SOON SO2000 Instructions Et Avertissements Pour L'installateur

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 34

11.1) Check of number of manoeuvres performed

The function "Maintenance notification" enables the user to check the number of manoeuvres performed as a percentage of the set limit.
To check, proceed as follows:
1.
Press and hold [Set] for approx. 3s
2.
Release [Set] when led L1 starts flashing.
3.
Press keys [▲] or [▼] to move the flashing led to L7, i.e. the "input led" associated with the parameter to be "Maintenance notification"
4.
Press and hold [Set] during steps 5, 6 and 7
5.
Wait approx. 3s after which the led associated with the current level of the parameter "Maintenance notification" will light up.
6.
Briefly press keys [▲] and [▼].
7.
The led corresponding to the selected level flashes a few times. The number of flashes indicates the percentage of manoeuvres
performed (in multiples of 10%) with respect to the set limit. For example: when the maintenance notification is set on L7 i.e. 10000, 10%
corresponds to 1000 manoeuvres; if the indicator led flashes 4 times, this means that 40% of the maximum number of manoeuvres
has been reached (i.e. between 4000 and 4999 manoeuvres). If 10% has not yet been reached, the led does not flash at all.
8.
Release [Set]

11.2) Manoeuvre counter reset

After performing system maintenance the manoeuvre counter must be reset. Proceed as described in table:
1.
Press and hold [Set] for approx. 3s
2.
Release [Set] when led L1 starts flashing.
3.
Press keys [▲] or [▼] to move the flashing led to L7, i.e. the "input led" associated with the parameter "Maintenance notification"
4.
Press and hold [Set] during steps 5 and 6
5.
Wait approx. 3s after which the led associated with the current level of the parameter "Maintenance notification" will light up.
6.
Press and hold keys [▲] and [▼] for at least 5 seconds, then release. The led corresponding to the selected level shows a series of
quick flashes to indicate that the manoeuvre counter has been reset.
7.
Release [Set]

12) Fault log list

SOON enables the display of any faults that have occurred in the last 8 manoeuvres, for example interruption of a manoeuvre due to activa-
tion of a photocell or sensitive edge. To check the list of faults, proceed as follows:
1.
Press and hold [Set] for approx. 3s
2.
Release [Set] when led L1 starts flashing.
3.
Press keys [▲] or [▼] to move the flashing led to L8, i.e. the "input led" associated with the parameter "Fault log"
4.
Press and hold [Set] during steps 5 and 6
5.
Wait approx. 3s after which the leds corresponding to the manoeuvres subject to faults will light up. Led L1 indicates the result of
the most recent manoeuvre, while led L8 indicates the result of the eighth manoeuvre. If the led is lit this means that faults have
occurred during the manoeuvre; if off this means that the manoeuvre was completed without faults.
6.
Press the keys [▲] and [▼] to select the required manoeuvre: The corresponding led emits a number of flashes equal to those
normally emitted by the flashing light after a fault.
7.
Release [Set]

13) Connecting other devices

If external devices need to be powered, such as a proximity reader
for transponder badges or the lighting of a key-operated selector
switch, power can be supplied as shown in figure 12. The supply
voltage is 24Vcc -30% ÷ +50% with maximum available current of
100mA.
12
GB
15

Publicité

Table des Matières
loading

Table des Matières