VM Motori D700 Série Manuel D'instructions page 118

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Problem
Output reduction
The battery war-
ning light comes
on
The oil pressure
warning light co-
mes on
GB
English
Cause
Clogged fuel filter
Presence of air in the fuel supply circuit
Injection pump malfunction
Dirty or faulty injectors
Clogged air filter
Engine overheating
Insufficient combustion air flow
The alternating current generator does
not charge the battery
Engine oil pressure too low
- 56 -
D700/750 E2-E3
Remedy
Replace filter (See "Fuel filter replacement")
Carry out bleeding (See "Fuel supply circuit
bleeding")
Replace the pump.
Apply to an authorised workshop
Replace the injectors.
Apply to an authorised workshop
Clean or replace the filter
Apply to an authorised workshop
Apply to an authorised workshop
Check and, if appropriate, replace the alter-
nating current generator.
Apply to an authorised workshop
Apply to an authorised workshop