Rated Data For 480 V Mains Voltage - Lenze 9300 vector Série Instructions De Montage

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3.3.2

Rated data for 480 V mains voltage

Basis of the data
AC mains connection
DC−mains connection
(alternatively)
Output voltage
With mains choke
Without mains choke
9300
Mains current
With
Mains choke
Mains choke
Type
I
[A]
r
EVF9321−xV
1.5
EVF9322−xV
2.5
EVF9323−xV
3.9
EVF9324−xV
7.0
EVF9325−xV
12.0
EVF9326−xV
20.5
EVF9327−xV
29.0
EVF9328−xV
42.0
EVF9329−xV
55.0
EVF9330−xV
80.0
EVF9331−xV
100
EVF9332−xV
135
EVF9333−xV
165
1)
Mains currents at a switching frequency of 8 kHz
2)
Switching frequency of the inverter
3)
Power supplied by the DC bus when operating with power−adapted motor
EDKVF9333V DE/EN/FR 7.2
Operation with rated power (normal operation)
Voltage
[U
]
3/PE AC 384 V − 0 % ... 528 V + 0 %
N
[U
]
DC 540 V − 0 % ... 740 V + 0 %
DC
3 ~ 0 approx. 94 % V
3 ~ 0 ... U
1)
Typical motor power
Without
ASM
(4−pole)
I
[A]
P
[kW]
P
r
rated
rated
2.1
0.37
3.5
0.75
5.5
1.5
˘
3.0
16.8
5.5
˘
11.0
43.5
18.5
˘
30.0
˘
37.0
˘
55.0
˘
75.0
˘
90.0
˘
110.0
˘
Operation allowed only with mains choke or mains filter
l
Technical data
Rated data for 480 V mains voltage
rated
N
Output power
2)
2/4 kHz
8 kHz
U, V, W
U, V, W
[hp]
S
[kVA]
S
rated
rated
0.5
1.2
1.2
1.0
2.1
2.1
2.0
3.2
3.2
4.0
5.8
5.8
7.5
10.8
10.8
15.0
18.5
18.5
25.0
26.6
26.6
40.0
39.1
39.1
50.0
49.9
49.9
75.0
69.8
69.8
100
91.4
91.4
125
124
124
150
158.2
149
Frequency
45 Hz − 0 % ... 65 Hz + 0 %
˘
˘
˘
Power loss
2)
3)
+U
, −U
G
G
[kVA]
P
[kW]
P
[W]
DC
loss
2.3
50
0.9
65
0
100
2.5
150
0
210
0
390
11.8
430
4.6
640
0
810
5.9
1100
0
1470
32.4
1960
47.1
2400
3
139