Lenze 9300 vector Série Instructions De Montage page 142

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3
Technical data
Operation with increased rated power
Rated data for 400 V mains voltage
9300
Rated output current at switching frequency
2/4 kHz
Type
I
[A]
r
EVF9321−xV
1.8
EVF9322−xV
3.0
EVF9323−xV
5.5
EVF9324−xV
9.2
EVF9325−xV
15.0
EVF9327−xV
43.0
EVF9328−xV
56.0
EVF9329−xV
66.0
EVF9330−xV
100
EVF9331−xV
135
EVF9332−xV
159
EVF9333−xV
205
Bold print = Lenze setting
1)
The currents apply to a periodic load change with an overcurrent time of maximally 1 minute and a base load time
of 2 minutes with maximally 75 % I
2)
Power−optimised operation with automatic switching frequency reduction. During operation with increased rated
power, the switching frequency is reduced to 2 kHz.
142
Max. permissible output current at switching
2)
2/8 kHz
2/4 kHz
I
[A]
I
r
1.8
3.0
5.5
9.2
15.0
43.0
56.0
66.0
100
135
159
205
rated
l
1)
frequency
2/8 kHz
[A]
I
max
max
2.2
3.7
5.8
10.5
10.5
19.5
19.5
48.0
48.0
70.5
70.5
89.0
89.0
134
134
165
165
225
225
270
270
EDKVF9333V DE/EN/FR 7.2
2)
[A]
2.2
3.7
5.8

Publicité

Table des Matières
loading

Table des Matières