Lenze 9300 vector Série Instructions De Montage page 166

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5
Electrical installation
Installation according to EMC (installation of a CE−typical drive system)
L1
L2
L3
N
PE
PES
PES
IN1
X11
IN2
K31
IN3
K32
IN4
33
34
PES
PES
X5
28
E1
E2
E 3
E4
E5
+
ST1
DC 24 V
ST2
39
PE
A1
A2
A3
A4
59
PES
PES
T1 T2
PES
PES
Fig. 5−1
166
F1 ... F3
K10
PE
Z2
PE L1 L2 L3
X4
HI
LO
GND
PES
X6
63
7
62
7
EVF9321 ...
4
EVF9333
3
2
1
PES
PE
X8
X9
X10
PE U
V
W
+UG
-UG
PE
PES
X8/8
X8/5
PES
KTY
J>
PES
M
PE
PE
3~
Example for wiring in accordance with EMC regulations
F1 ... F3
Fuses
K10
Mains contactor
Z1
Programmable logic controller (PLC)
Z2
Mains choke or mains filter
Z3
Brake chopper EMB9352−E
Z4
Brake resistor
S1
Mains contactor on
S2
Mains contactor off
+U
, −U
DC−bus connection
G
G
PES
HF shield termination through large−surface connection to PE
l
PES
PES
PE
PE
+UG
-UG
9352
PES
M
3~
S2
K10
S1
PES
PES
PES
PES
PE
RB2
RB1
PE
RB1
RB2
T1
T2
RB
JRB
Z3
9300VEC108
EDKVF9333V DE/EN/FR 7.2
K10
PES
PES
Z4

Publicité

Table des Matières
loading

Table des Matières