Terminal data
(
Stop!
ƒ
ƒ
ƒ
Cable type
Rigid
Flexible
Flexible
Flexible
EDKVF9333V DE/EN/FR 7.2
Connect or disconnect the terminal strips only if the controller is
disconnected from the mains!
Wire the terminal strips before connecting them!
Unused terminal strips must also be plugged on to protect the contacts.
Wire end ferrule
Without wire end
ferrule
Wire end ferrule
without plastic sleeve
Wire end ferrule with
plastic sleeve
l
Electrical installation
Control terminals
Important notes
Maximum cable
Tightening torque Stripping
cross−section
2
2.5 mm
(AWG 14)
2
2.5 mm
(AWG 14)
0.5 ... 0.6 Nm
(4.4 ... 5.3 lb−in)
2
2.5 mm
(AWG 14)
2
2.5 mm
(AWG 14)
5
length
5 mm
205