Lenze 9300 vector Série Instructions De Montage page 160

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4
Mechanical installation
Standard devices in the power range of 55 kW
Modification of the fan module for push−through technique
Plugging the fan connecting cable to another terminal on the fan module
Fig. 4−13
1. Remove the cable lugs of the two red connecting cables and plug them in again on
the diagonally arranged side.
2. Remove the cable lugs of the two blue connecting cables and plug them in again on
the diagonally arranged side.
Mounting the fan module in a manner rotated by 180°
Fig. 4−14
1. Place the fan module onto the controller. Insert the lugs at the back into the base
plate 0.
Make sure that the threaded sleeves do not touch the housing edge. They may break
off.
2. Push the fan module to the front.
3. Screw−in and fasten the 4 screws for fixing the fan module on each side.
4. Screw−in and fasten the two screws for the supply voltage.
160
Plugging the fan connecting cable for the voltage supply to another terminal
Mounting the fan module on the controller
l
9300vec173
9300vec172
EDKVF9333V DE/EN/FR 7.2