Mounting
Apply heat conducting paste before screwing together the cooler and cooling plate of the
drive controller so that the heat transfer resistance is as low as possible.
1. Fasten the fixing bracket with sheet metal screws 3.5 × 13 mm at the top and
bottom of the drive controller 3.
2. Clean the contact surface of cooler and cooling plate with spirit.
3. Apply a thin coat of heat conducting paste with a filling knife or brush.
– The heat conducting paste in the accessory kit is sufficient for an area of approx.
1000 cm
4. Mount the drive controller on the cooler.