Lenze 9300 vector Série Instructions De Montage page 138

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3
Technical data
Operation with rated power (normal operation)
Rated data for 400 V mains voltage
9300
Rated output current at switching frequency
3)
2/4 kHz
8 kHz
Type
I
[A]
I
r
r
EVF9321−xV
1.5
1.5
EVF9322−xV
2.5
2.5
EVF9323−xV
3.9
3.9
EVF9324−xV
7.0
7.0
EVF9325−xV
13.0
13.0
EVF9326−xV
23.5
23.5
EVF9327−xV
32.0
32.0
EVF9328−xV
47.0
47.0
EVF9329−xV
59.0
59.0
EVF9330−xV
89.0
89.0
EVF9331−xV
110
110
EVF9332−xV
150
147
EVF9333−xV
180
147
Bold print = Lenze setting
1)
The currents apply to a periodic load change with an overcurrent time of maximally 1 minute and a base load time
of 2 minutes with maximally 75 % I
2)
Power−optimised operation with automatic switching frequency reduction. When the max. permissible output
current is exceeded, the switching frequency is reduced to 2 kHz.
3)
Possible for some types in case of other operating conditions: Operation with increased rated output current at the
same load change (see chapter "Operation with increased rated power")
138
2)
8 kHz sin 8/2 kHz
[A]
I
[A]
I
[A]
r
r
1.5
1.5
2.5
2.5
3.9
3.9
7.0
7.0
13.0
13.0
23.5
23.5
29.0
32.0
43.0
47.0
47.0
59.0
59.0
89.0
76.0
110
92.0
150
100
180
rated
l
Max. permissible output current at switching
16 kHz
2/4 kHz
8 kHz
I
[A]
I
[A]
I
[A]
r
max
max
1.1
2.2
2.2
1.8
3.7
3.7
2.9
5.8
5.8
5.2
10.5
10.5
9.7
19.5
19.5
15.2
35.0
35.0
21.0
48.0
48.0
30.0
70.5
70.5
35.0
89.0
89.0
46.0
134
134
52.0
165
165
58.0
225
221
63.0
270
221
1)
frequency
2)
8 kHz sin 8/2 kHz
16 kHz
I
[A]
I
[A]
I
[A]
max
max
max
2.2
2.2
1.6
3.7
3.7
2.7
5.8
5.8
4.3
10.5
10.5
1.8
19.5
19.5
14.5
35.0
35.0
22.9
43.0
48.0
31.0
64.0
70.5
46.0
70.0
89.0
53.0
88.0
134
69.0
114
165
165
138
225
87.0
150
270
94.0
EDKVF9333V DE/EN/FR 7.2

Publicité

Table des Matières
loading