Lenze 9300 vector Série Instructions De Montage page 185

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2.5 Nm
T1
22,1 lb-in
T2
4
T1
T2
1
0
Fig. 5−12
EDKVF9333V DE/EN/FR 7.2
Standard devices in the power range 15 ... 30 kW

2
}
PE
+
3
PE
U
V
M 6
U, V, W,
5 Nm
PE
44 lb-in
Motor connection with PTC thermistor or thermal contact (NC contact)
 0
Motor connection with Lenze system cable with integrated control cable for the motor
temperature monitoring
1
Shield sheet
Clamp entire shield and shield of the control cable for the motor temperature monitoring
with the straps. If required, fix by means of cable tie.
‚ 0
Motor cable connection and separate control cable for the motor temperature monitoring
1
Shield sheet
Clamp shield of the motor cable and shield of the cable for the motor temperature
monitoring with the straps. If required, fix by means of cable tie.
2
PE stud
PE cable connection with ring cable lug
3
U, V, W
Motor cable connection
Check the correct polarity. Observe maximum length of the motor cable.
Max. connectable cable cross−section: 50 mm
4
T1, T2 for motor temperature monitoring
Cable connection for PTC thermistors or thermal contacts (NC contacts)
l
Electrical installation
Motor connection
2
2.5 Nm
T1
22,1 lb-in
T2
4
T1
W
T2
1
0
2
with ring cable lug
PE
}
PE
+
9300std030
185
5

Publicité

Table des Matières
loading

Table des Matières