14. DIAGNOSTICS

14.1

Error messages

The following Error messages may appear on the E86N interface unit display:
ALARM
MESSAGE
E.E2
Read/write error
No antenna connected
E.nb
Incorrect antenna connection
E.b1
Error communicating with antenna 1
E.b2
Error communicating with antenna 2
F.P1
Fault (short-circuit) on PROBE 1 output
F.P2
Fault (short-circuit) on PROBE 2 output
F. Er
Fault (short-circuit) on ERROR output
Fault (short-circuit) on LOW_BAT output
F. Lb
F. Au
Fault (short-circuit) on AUX output
Note:
After the causes of the errors have been eliminated, you can clear the indications from the display by pressing the <Select>
and <Enter> keys simultaneously for longer than 2 seconds (except messages E.b1 and E.b2 which are cleared when you
power down then power up again).
CAUTION:
All system switch off and switch on operations must be performed with the antenna connector(s) connected.
14.2

LED indications

The LEDs on the interface unit panel can give the following indications:
"POWER" LED OFF
No power supply
Resettable fuse open
"ERROR" LED ON
Transmitter – antenna outside transmission range Make sure that during probe movements the green
Transmitter battery completely flat or missing
Transmission time elapsed
No electrical connection between antenna and
interface
Electrical or electromagnetic interference
"PROBE" LED:
No electrical connection between probe and
transmitter.
DOES NOT CHANGE
STATUS WHEN
Probe damaged
PROBE TOUCHES
Transmitter damaged
POOR
Loose finger
REPEATABILITY
Loose flange
Internal seal pierced or damaged.
mida
CAUSE
CAUSE
SOLUTION
Contact the Technical Assistance service or reprogram all of the data.
Check the connection to the antenna.
Check that if there is only one antenna it is connected to the lower
terminal (H1) on the interface.
Check the connection to antenna 1.
Check the connection to antenna 2.
Check the connection to the PROBE 1 output.
Check the connection to the PROBE 2 output.
Check the connection to the ERROR output.
Check the connection to the LOW_BAT output.
Check the connection to the AUX output.
Check for voltage at the ends of terminals 16 and 17 on
the interface unit terminal board.
Wait several minutes with the interface powered down.
""tuning"" LED on the receiver remains lit.
Change the battery
Give a start signal to reactivate the system.
Check the receiver cable and the relative connections
to the interface.
Move the cable from the antenna away from any power
cables. Change the operating channel.
Check the connection between the probe and the
transmitter.
Remove the probe from the transmitter, connect the
sprung contacts to one another and interrupt the
contact. If despite this the LED does not change status,
the transmitter is faulty. If it changes status, the probe is
faulty.
Check that the finger and crash protection pin (if used)
are tightened on the probe.
Tighten all of the screws.
Substitute the probe.
SOLUTION