Interface Unit Dimensions; E86N Interface Technical Specifications - marposs E86N Manuel D'installation Et D'utilisation

Detecteur touch a transmission radio
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

ENGLISH

9.2 Interface unit dimensions

Figure 9-2. Overall dimensions.

9.3 E86N Interface technical specifications

Power supply
: 24V DC unstabilised (13.5 - 35 V)
: 300 mA max. (with two antennas connected)
Input Signals
: Optoisolated inputs (24V - <10mA)
-
AUX IN
: Not connected (for future use)
-
SEL 0 - SEL 1
: Identification code selection, for selecting up to 4 transmitters on the same machine (see sec. 9.4.1
-
START/STOP
: Transmission Activation/Deactivation.
24V – 4mA
The operating voltage/current of this input can be programmed according to the type of NC connected (see
sec. 10.1 "Programming the interface" on page 72) with the following values:
15V – 0.5 mA (Low current)
Note:
The connection of input signals may be of the SINK type (connect "COM" to "+24V") or the SOURCE type
(connect "COM" to "0V").
Output Signals
: Solid State Relay (SSR) Contacts 50V - 40 mA
-
ERROR
: Communication error
-
AUX OUT
: Not connected (for future use)
-
PROBE 1/SKIP
: Signal relative to the status of the probe being used; may be programmed as a probe status signal (in
-
PROBE 2/SKIP
: Additional signal relative to the status of the probe being used; may be programmed as a probe status
-
LOW BAT
: Low battery signal with battery level on display equal to "3".
68
70
(2,76")
"Selecting the identification code" on page 69).
24V - 7 mA
(High current)
(probe not activated or outside the transmission range, transmitter battery completely flat with battery level
on display equal to "0".
N.C. (Normally Closed) contact.
home position or deflected) or SKIP (pulse).
Programmable N.C. or N.O. (Normally Closed or Normally Open) contact.
signal (in home position or deflected) or SKIP (pulse).
Programmable N.C. or N.O. (Normally Closed or Normally Open) contact.
Using an alkaline battery the remaining continuous system operation in this condition is:
14 hours for the Standard transmitter
24 hours for the Compact transmitter
Programmable N.C. or N.O. (Normally Closed or Normally Open) contact.
11
(0,43")
51
(2,01")
E86N- Touch system with radio transmission