9. E86N INTERFACE UNIT

9.1 Interface unit front panel

Figure 9-1: Front panel.
A - "Power" LED (green)
B - "Probe" LED (green)
C - "Low battery" LED
(yellow)
D - "Error" LED (red)
E - DISPLAY
F - ENTER KEY
G – SELECT KEY
H – TERMINAL BOARD
I - TERMINAL BOARD
mida
H2
I
H1
: lit when the power supply voltage is present.
: indicates the probe status. Lit when the probe finger is deflected. Off when the probe finger is in the
home position.
: lit when the battery is almost flat (see sec. 7.2 "Battery life and indications on the Interface " on page
61 and LOW BAT output signal sec. 9.4 "Connections to the interface unit" on page 69).
: indicates an error condition. Lit when the transmission is not activated, when the probe is outside the
transmission range (see also ERROR output signal sec 9.4 "Connections to the interface unit" on
page 69) and when the battery is completely flat (see sec. 7.2 "Battery life and indications on the
Interface" on page 61).
: seven-segment, three-digit LED display. In normal operating conditions, this can show the radio
channel operating, the identification code and the battery charge status.
During programming it shows all programmable values.
: Press for longer than 2 seconds to switch the interface to programming mode.
In programming mode, confirms the selected data item and moves on to the next.
Press for longer than 2 seconds simultaneously with the <Select> key to clear the alarm messages
present on the interface display.
: Press for less than
2 seconds to view the identification code on the left and the battery charge
level on the right
Press for longer than 2 seconds for system manual Activation/Deactivation.
Press for 2 seconds simultaneously with the <Enter> key to clear the alarm messages present on
the interface display.
In programming mode, scans the programmable data or increases the current programming
data item.
: for connecting the single antenna (H1) and the additional antenna (H2).
CAUTION
When using only one Antenna, in order to make it function correctly always connect it to the lower
terminal H1. Otherwise, if you connect it to the upper terminal H2, the system does not function and
the display shows the "E.nb" error message (see sec. 14.1 "Error messages" on page 87).
: For electrical connections to the CNC.