Programming the interface

Switch to programming mode and select the type of programming "I" with the "Select" and "Enter" keys to edit one or more of the
following values:
Note: after you have confirmed the last data item you exit programming.
However, you can exit programming at any time by holding down the <ENTER> key for longer than 2 seconds, cancelling the
current sequence.
72
> 2 seconds
Channel entry:
TENS
Channel entry:
UNITS
Probe 1 output polarity:
P1C= N.C. OUTPUT
P1O= N.O. OUTPUT
Probe 1 output functionality:
P1P= PROBE STATUS
P1S= SKIP
Probe 2 output polarity:
P2C= N.C. OUTPUT
P2O= N.O. OUTPUT
Probe 2 output functionality:
P2P= PROBE STATUS
P2S= SKIP
LOW BAT output mode:
LbC= N.C.
LbO= N.O.
PROBE error output:
PE0= Probe at 0 (home)
PE1= Probe at 1(deflected)
START signal:
S= Standard
P= Pulse
r= retrigger
START input:
L= low current
15V-0.5mA
H= normal current
24V-4mA
Remote display on base st.:
0= disabled
1= enabled
Auto. ch. programming:
0= disabled
1= enabled
Number of
switch ON/switch OFF attempts
Confirm data programmed:
0= not confirmed
1= confirmed