Route the battery connector cables (only use the original
Truma cables supplied) to the control unit and attach them
securely using the clips and screws provided.
Figure 33
The battery connector cables must not be extended.
They must be routed separately from the motor cables,
and must not run over the control unit.
Route battery connector cables so that they do not chafe
(particularly at leadthroughs through metal panels). Use
suitable protective leadthrough bushing to prevent damage
to cables. Connect battery connector cables to the existing
battery terminals (red = positive, black = negative).
Incorrect polarity will destroy the electronics / control
unit
The connection to the control unit (as per the connecting dia-
gram) must be made in the order: nut, battery connection ring
eyelet, nut (torque M6 = 6.0 Nm).
Connect fuse in the positive lead (150 A) near the positive ter-
minal of the battery.

Connecting the safety socket

Route the 2-wire cable provided (9 m or 10 m) with the flat
connectors through the socket holder (g) and the rubber
sleeve (h).
If necessary, open cover and push socket connection out of
socket housing (i).
Connect 2-wire cable with flat connectors to micro switch.
RD / BK
Figure 34
If necessary, insert socket connector back into socket housing (i).
Screw socket housing (i) with rubber seal (h) to socket
holder (g) using 3 sheet metal screws (j). (Several positions
are possible by selecting the mounting holes on the socket
holder and rotating the rubber seal)
Lead cable loosely through the strain relief (k) and screw in
place with the 2 sheet metal screws. Depending on the instal-
lation situation, the cable can be led out of the socket holder
through one of the three recesses.
Figure 35
Secure safety socket to the (plastic) shaft cover of the caravan
with 4 screws, nuts and washers.
Figure 36
the two clips.
Figure 37
Route both wires to the control unit (shortening them if necess-
ary) and connect them to the connector block as shown in the
connecting diagram.
Re-check whether all cables are correctly connected, attached
using the provided clips and cannot chafe.
BK
h
g
PT 4 x 10
M4 x 16
(4 x)
Washer 4.3
(4 x)
Nut M4 (4 x)
No holes must be drilled in the chassis.
Alternatively, the safety socket can be secured using
i
B 3.9 x 33
(3 x)
j
k
EN
29