Annex
Annex
A1
Synchronisation
It is necessary to perform synchronisation in case of
malfunctions or after the electronic components
have been renewed.
Proceed as follows when doing this:
If the remote control is on,
it must be switched off.
Switch on the system at the
master switch.
Press and hold the reset button on the base station.
Now switch on the remote control. The
LED of the remote control must now light
up. Then switch the remote control off
again within 2 seconds.
This completes the synchronisation.
A2
Reset
The reset procedure is only required if the LED on the base
control unit lights up during operation. This is a fault signal
(e. g. overvoltage/overload/excessive temperature) – nor-
mally, the LED is switched off.
The reset resets the fault.
Perform a reset by switching
off the master switch.
Alternatively, it is possible to press the
reset button on the base control unit
when the remote control is switched on.
} Caution:
Please contact your dealer if the LED keeps flashing even
after several resets and allowing time for the equipment
to cool down.
A3
Emergency mode
Swivelling the drive rollers away manually
Pry the yellow operating lever out of the rear of the housing
using a suitable screwdriver until it can be rotated over the
housing. (Fig. Annex 1)
Turn clockwise = swivel towards the tyre – ON
(Figs. Annex 2 and Annex 3)
Turn anticlockwise = swivel away from the tyre – OFF
(Figs. Annex 2 and Annex 4)
} Caution:
Always move the drive unit as far as its limit
position in either direction!