4. Install the cover plates (3) and (4) to the back of
the stove.
Install the smallest plate first.
5. Unscrew the round cover lid from the top plate.
6. Place the top plate back on the stove before the
connection duct is installed.

Closed system connection

The concentric exhaust system allows for a series of
connection options for this appliance:
Through the facade, at any height, with or without
horizontal or oblique joint.
Through the roof, with or without horizontal or
oblique joint.
Through an existing flue gas exhaust pipe (chim-
ney)
First place the stove, see section "General pre-
paration". The concentric duct system can then be put
together in steps, starting at the stove.
Structural conditions may make it necessary
for (part of) the concentric duct system to be
built in first.
Facade sleeve through a facade of
non-flammable material
Read the "Installation Conditions" chapter care-
fully and follow the installation instructions
below.
The following illustration shows the situation of a fin-
ished facade sleeve.
Subject to change because of technical improvements
1. Start at the stove and add the concentric pipes
one component at a time along the route you
decided on in advance.
2. Next, install a concentric elbow and possible hori-
zontal change in direction and decide on the loc-
ation of the sleeve.
3. Make a 10 mm larger hole in the facade in such a
way that the air intake duct drains to the outside.
Use a 1 - 3 degree angle or a slope percentage of 2
-5% for this.
Prevent dust and/or grit from getting into the
stove when drilling.
4. Decide on the length of the facade sleeve and
shorten the intake to the wall if necessary. Allow
the flue gas duct to extend approximately 10 mm
from the air intake duct.
Use tin-snips to shorten the air intake cover
(0.5 mm).
Use a hacksaw to shorten the flue gas duct
(0.6 mm).
Grinding is not recommended as it burns stain-
less steel.
5. Remove burrs and sawdust.