ANNEXE
Table 18 : Example: "Command type" "Command"
<"Start of
text">"Command type value (ASCII)""space""Command value
(ASCII)""space""Parameter value
Copy example with framing (ASCII)
CoLa A
Copy example without framing (ASCII)
Copy example with framing (Hex)
"Start of text and given length"
value (Binary)""Parameter value
CoLa B
Copy example without framing (Binary)
Table 19 : Telegram structure: "Command type" "Command" (Answer)
Telegram structure: "Command type" "Command"
Telegram
Description
part
Lists the
Describes the corre‐
different
sponding telegram
parts of
parts.
the tele‐
gram.
Table 20 : Example: "Command type" "Command" (Answer)
CoLa A <"Start of
text">"Command type value (ASCII)""space""Command value
(ASCII)""space""Parameter value
<"Start of
text">"Command type value (Hex)""space""Command value
(Hex)""space""Parameter value
CoLa B "Start of text and given
value (Binary)""Parameter value
12.3.1.4.1

Log in [sMN SetAccessMode]

NOTE
Please note that the laser is shut off after a succesful log in and no measurement data is created any more.
The laser is turned on again after log out
An automated hash-value calculator can be found in SOPAS ET under menu "password". Required userlevel
'Service'
(see « Change password [sMN SetPassword] », page
A log in to the device is necessary to change parameters. In most cases, the user level 'Authorized client' is
needed. Changed parameters will be reset to the previous state via a reboot unless the are saved. To save
parameter changes the command "sMN mEEwriteall"
page
74) must be send before log out.
Table 21 : Telegram structure: sMN SetAccessMode
Telegram structure: sMN SetAccessMode
Telegram
Description
part
Command
Method
type
Command User level
68
N O T I C E D ' I N S T R U C T I O N | TiM781
(ASCII)"<"End of text">
"Command type value (Binary)""space""Command value
(Binary)""Calculated checksum"
Variable
Length
Additional details
Defines
Defines
Gives further information
the type
the
regarding the values in CoLa
of the
length
A/ CoLa B if neccessary.
variable.
in byte.
(ASCII)"<"End of text">
(Hex)"<"End of text">
length""Command type value (Binary)""space""Command value
(Binary)""Calculated checksum"
(see « Set to run [sMN Run] », page
(see « Save parameters permanently [sMN mEEwriteall] »,
Variable
Length
String
3
String
13
(ASCII)""space""Parameter value
Values CoLa A
(ASCII)
Defines the
value of the
telegram part in
CoLa A (ASCII).
(ASCII)""space""Parameter value
(Hex)""space""Parameter value
75).
72).
Additional details
Values CoLa A
sMN
SetAccessMode 53 65 74 41
(Binary)""space""Parameter
Values CoLa B
(Binary)
Defines the
value of the
telegram part in
CoLa B (Binary).
(Binary)""space""Parameter
Values CoLa B
(ASCII)
(Binary)
73 4D 4E
63 63 65 73
73 4D 6F 64
65
8024232/1ONO/2024-09-25 | SICK