Telegram structure: sRA ActiveFieldSet
Telegram
Description
part
Active
Fieldset
Table 201 : Example: sRA ActiveFieldSet
<STX>sRA{SPC}ActiveFieldSet{SPC}F<ETX>
CoLa A
02
73 52 41
20
41 63 74 69 76 65 46 69 65 6C 64 53 65 74
CoLa B 02 02 02 02 00 00 00 15
12.3.1.5
Diagnostics
12.3.1.5.1
SOPAS error codes
sFA ErrorCode
Table 202 : SOPAS error codes
Error code
Sopas_Ok
Sopas_Error_METHODIN_ACCESSDENIED
Sopas_Error_METHODIN_UNKNOWNINDEX
Sopas_Error_VARIABLE_UNKNOWNINDEX
Sopas_Error_LOCALCONDITIONFAILED
Sopas_Error_INVALID_DATA
Sopas_Error_UNKNOWN_ERROR
Sopas_Error_BUFFER_OVERFLOW
Sopas_Error_BUFFER_UNDERFLOW
Sopas_Error_ERROR_UNKNOWN_TYPE
Sopas_Error_VARIABLE_WRITE_ACCESSDENIED
Sopas_Error_UNKNOWN_CMD_FOR_NAMESERVER When using names instead of indices, a command
Sopas_Error_UNKNOWN_COLA_COMMAND
Sopas_Error_METHODIN_SERVER_BUSY
8024232/1ONO/2024-09-25 | SICK
Subject to change without notice
Variable
Length
Uint_16
2
73 52 41
20
41 63 74 69 76 65 46 69 65 6C 64 53 65 74
Telegram structure: sFA ErrorCode
No error
Wrong userlevel, access to method not allowed
Trying to access a method with an unknown Sopas
index
Trying to access a variable with an unknown Sopas
index
Local condition violated, e.g. giving a value that
exceeds the minimum or maximum allowed value
for this variable
Invalid data given for variable, this errorcode is dep‐
recated (is not used anymore).
An error with unknown reason occurred, this error‐
code is deprecated.
The communication buffer was too small for the
amount of data that should be serialised.
More data was expected, the allocated buffer could
not be filled.
The variable that shall be serialised has an
unknown type. This can only happen when there
are variables in the firmware of the device that do
not exist in the released description of the device.
This should never happen.
It is not allowed to write values to this variable.
Probably the variable is defined as read-only.
was issued that the nameserver does not under‐
stand.
The CoLa protocol specification does not define the
given command, command is unknown.
It is not possible to issue more than one command
at a time to an SRT device.
Additional details
Values CoLa A
1h ...10h
20
46
03
Description
N O T I C E D ' I N S T R U C T I O N | TiM781
12
ANNEXE
Values CoLa B
(ASCII)
(Binary)
00 01
...
00 10
20
00 0F
43
Dec.
Hex.
0
0
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
A
11
B
12
C
13
D
119