7
Parameterisation 8200 vector/8200 motec
Transmit parameter sets
Step
l
Copy individual parameter sets (PARx and, if applicable, FPAR1) to the standard device:
– Standard device with
function module
Application I/O,
INTERBUS,
PROFIBUS−DP, LECOM−B,
DeviceNet, CANopen
– Standard device
including all other
function modules or
standard device without
any function modules
7.
Start copying
8.
Change to the code level
9.
Enable the controller
82
Key sequence
z
T V
V
A
V
B
U
l
Action
Copy PAR1 and FPAR1:
ð
Set "71" "Key−>FP1&PAR1"
Copy PAR2 and FPAR1:
ð
Set "72" "Key−>FP1&PAR2"
Copy PAR3 and FPAR1:
ð
Set "73" "Key−>FP1&PAR3"
Copy PAR4 and FPAR1:
ð
Set "74" "Key−>FP1&PAR4"
Copy PAR1:
ð
Set "11" "Keypad−>PAR1"
Copy PAR2:
ð
Set "12" "Keypad−>PAR2"
Copy PAR3:
ð
Set "13" "Keypad−>PAR3"
Copy PAR4:
ð
Set "14" "Keypad−>PAR4"
The selected parameter sets are copied to
the standard device or to the function
module.
"LOADING..." is displayed.
If "LOADING ..." goes out, the copying
process has been completed.
The operating level is displayed
"Param managm" is displayed in C0002
The drive restarts
EDK9371BC DE/EN/FR 3.1