Transmit parameter sets
The keypad enables you to copy parameter settings from one standard device to another.
Use "Param managm" in menu 7 for this purpose:
Copy parameter sets from the standard device to the keypad
Step
1.
Connect the keypad to
standard device 1
2.
Inhibit the controller
3.
Select the "Load/Store"
submenu 7.1 in the "Param
managm" menu 7
4.
Change to the code level
5.
Change to the parameter level
6.
Select the correct copy function
l
Copy all available parameter sets (PAR1 ... PAR4, FPAR1 if applicable) into the keypad:
– Standard device with
function module
Application I/O,
INTERBUS,
PROFIBUS−DP, LECOM−B,
DeviceNet, CANopen
– Standard device with all
other function modules
l
Only copy the module−specific parameter set FPAR1 to the keypad:
– Only possible for
standard devices with
function module
INTERBUS,
PROFIBUS−DP, LECOM−B,
DeviceNet, CANopen:
EDK9371BC DE/EN/FR 3.1
Parameterisation 8200 vector/8200 motec
Key sequence
S
z y Z Y
Z
V
z
z
l
Transmit parameter sets
Action
The drive coasts
Change to the "Load/Store" submenu
using the arrow keys
"Param managm" is displayed in C0002
"0" and "READY" are displayed
The settings stored in the keypad are
overwritten.
Copy PAR1 ... PAR4 and FPAR1:
ð
Set "80" "F1&PAR1−4−>Key"
Copy PAR1 ... PAR4:
ð
Set "20" "PAR1−4−>Keypad"
Copy FPAR1:
ð
Set "50" "FPAR1−>Keypad"
7
79