Télécharger Imprimer la page

Lenze EMZ9371BC Instructions De Mise En Service page 83

Publicité

Les langues disponibles

Les langues disponibles

Restoring default (as delivered) settings
Step
1.
Connect the keypad to the
standard device
2.
Inhibit the controller
3.
Select the "Load/Store"
submenu 7.1 in the "Param
managm" menu 7
4.
Change to the code level
5.
Change to the parameter level
6.
Select the correct copy function
l
Load parameter sets (PARx) into the standard device:
– Restore the delivery
status in the selected
parameter set of the
standard device
l
Load the parameter set (FPAR1) into the fieldbus function module:
– Restore the delivery
status in the fieldbus
function module
EDK9371BC DE/EN/FR 3.1
Parameterisation 8200 vector/8200 motec
Restoring default (as delivered) settings
Key sequence
S
z y Z Y
Z
V
z
z
l
Action
The drive coasts
Change to the "Load/Store" submenu
using the arrow keys
"Param managm" is displayed in C0002
"0" and "READY" are displayed
The settings stored in the standard
device or in the function module are
overwritten.
Load PAR1:
ð
Set "1" "Keypad−>PAR1"
Load PAR2:
ð
Set "2" "Keypad−>PAR2"
Load PAR3:
ð
Set "3" "Keypad−>PAR3"
Load PAR4:
ð
Set "4" "Keypad−>PAR4"
Load FPAR1
ð
Set "31" "Keypad−>FPAR1"
7
83

Publicité

loading

Ce manuel est également adapté pour:

E82zbbxcEdk9371bc