Step
9.
l
If the function "Copy all
parameter sets into the
EEPROM" (C0002 = 20) is
selected, they might have
to be loaded in the main
memory manually.
l
If the function "Copy
individual parameter sets
into the main memory"
(C0002 = 1x) is selected,
they might have to be
saved permanently in the
EEPROM manually.
10.
Plug in plugs X5 and X6
11.
Enable controller
EDK9371BC DE/EN/FR 3.1
Parameterisation 9300 series
Key sequence
Action
z y Z Y
Select code C0003 "PAR SAVE" in the
"Load/Store" menu using the arrow keys
and store the contents of the main
memory permanently.
Terminal X5/28 = HIGH
The drive is running with the new
settings.