Step
1.
Inhibit controller
2.
Load the saved parameter set
into the main memory
Select the parameter set
to be loaded
3.
Change to the code level
4.
Enable controller
EDK9371BC DE/EN/FR 3.1
Parameterisation 9300 series
Key sequence
z y Z Y
A
V
B
z
C
T V
D
V
A
V
B
l
Load parameter set
Action
Terminal X5/28 = LOW
Select the code C0002 "PAR LOAD" in the
menu "Load/Store"
Change to the parameter level
The active parameter set is displayed,
e. g. display "0" and "Load Default"
If you want to restore the delivery status,
proceed with D
Load parameter set 1:
ð
Set "1" "Load PS1"
Load parameter set 2:
ð
Set "2" "Load PS2"
Load parameter set 3:
ð
Set "3" "Load PS3"
Load parameter set 4:
ð
Set "4" "Load PS4"
"RDY" goes off. The parameter set is
loaded completely into the main memory
if "RDY" is displayed again.
Display of the operating level
Display of C0002 "PAR LOAD"
Terminal X5/28 = HIGH
The drive is running with the settings of
the loaded parameter set