Grease with the correct properties is available from all
major lubricant manufacturers.
Admixtures are recommended, but a written guarantee
must be obtained from the lubricant manufacturer
especially concerning EP admixtures, that admixtures
do not damage bearings or the properties of lubricants at
the operating temperature range.
WARNING
Lubricants containing EP admixtures are not
recommended in high bearing temperatures in
frame sizes 280 to 400.
If the ambient temperature is below -25°C or above
+55°C, or bearing temperature is above 110°C, consult
ABB Sales Office regarding suitable grease.
The following high performance grease can be used
Esso
Unirex N2, N3 or S2 (lithium complex base)
Mobil
Mobilith SHC 100 (lithium complex base)
Shell
Albida EMS 2 (lithium complex base)
SKF
LGHQ 3 (lithium complex base)
Klüber
Klüberplex BEM 41-132 (special lithium
base)
FAG
Arcanol TEMP90 (calsium polyurea base)
FAG
Arcanol TEMP110 (lithium complex base)
Lubrication intervals for other grease fullfilling the
required properties, contact your local ABB Sales
Office.
Lubrication intervals and amounts, 2-pole,
IEC frame sizes 280 and 400
Frame
size
Ball bearings
Lubrication intervals in duty hours
280
M2B*, M2C*, M3B*
315
M2B*, M2C*, M3B*
355
M2B*, M2C*
355
M3B*
400
M2B*, M2C*
400
M3B*
Roller bearings
Lubrication intervals in duty hours
280
M2B*, M2C*, M3B*
315
M2B*, M2C*, M3B*
355
M2B*, M2C*
355
M3B*
400
M2B*, M2C*
400
M3B*
NOTE!
Always use high speed grease for high speed machines
and some other models, e.g. M2BA 355 and 400 2-pole
machines, where the speed factor is higher than 400 000
(calculated as Dm x n where Dm = average bearing
diameter, mm; n = rotational speed, r/min).
ABB / Low Voltage Motors / Manual 11-2002
Amount
3600
3000
of grease
r/min
r/min
g/bearing
35
2000
3500
35
2000
3500
45
1200
2000
35
1200
2000
45
600
800
40
1000
1600
35
1000
1800
35
1000
1800
45
600
1000
35
600
1000
45
-
-
40
500
800
The following grease can be used:
FAG
L69 (polyurea base)
Klüber
Klüber quiet BH 72-102 (polyurea base)
SKF
LGHP2 (polyurea base)
If other lubricants are used, check with the manufacturer
that the qualities correspond to those of the above
mentioned lubricants, or if the compatibility of the
lubricant is uncertain, contact your local ABB Sales
Office.
Frequency converter drives
Higher speed operation, e.g. in frequency converter
applications, or lower speed with heavy load will require
shorter lubrication intervals. Consult your local ABB
Sales Office in such cases.
Typically a doubling of speed will require a reduction of
lubrication intervals to approx. 40 % of values tabulated
above.
WARNING
The constructional maximum speed of the motor
must not be exceeded.
Suitability of bearings for high speed operation must be
checked.

Spare parts

When ordering spare parts, the full type designation and
product code, as stated on the rating plate, must be
specified.
If the machine is stamped with a serial manufacturing
number, this should also be given.
Rewinding
Rewinding should always be carried out by qualified
repair shops.
Smoke venting and other special motors should not be
rewound without first contacting ABB.

5. Environmental requirements

Noise levels
Most of our motors have a sound pressure level not
exceeding 82 dB(A) refer to 50 Hz sinusoidal supply
conditions, tolerance ± 3 dB(A).
Values for specific machines can be found in the
relevant product catalogues.
For sound pressure levels for 60 Hz sinusoidal supply
and with non-sinusoidal supplies, contact ABB Sales
Office.
Sound pressure levels for all machines having separate
cooling systems and for series M2F*/M3F*, M2L*/M3L*,
M2R*/M3R*, and M2BJ/M2LJ are indicated in separate
Manuals.
9

Publicité

Table des Matières
loading

Table des Matières