1 1 8 8 . . F F u u n n c c t t i i o o n n a a n n d d a a d d j j u u s s t t m m e e n n t t o o f f t t h h e e r r e e f f e e r r e e n n c c e e s s w w i i t t c c h h
As standard, the drives of the drive portal 800i series are equipped with a
contactless magnetic switch as reference switch. The magnetic reference switch
is fixed in the console. The magnetic reference switch included in the
permanent magnet is attached according to the instructions included in the
accessory pack.
The distance between magnetic switch and magnet must not exceed 10 mm! If
the range of the magnets is not sufficient, a stronger magnet can be used.
Endschalter
The magnet must be mounted to the rack at any position between the positions
"OPEN" and "CLOSED". If the gate is also used in partial opening mode, the
position of the magnet should be between "CLOSED" and "Partial opening" e.g.
1 m before end position closed.
max. 10 mm
Magnet
Zahnstange
26