Replacing the base set and burner unit

• Apply the new type plate.
• Slide the interior back into the casing.
• Replace the burner mounting plate.
• Replace the burner tray without the airflow regulator.
• Replace the vermiculite tray.
• Position either the logs or the white carrara stones.
• Replace the glass pane.
• Fit the frame and front.
Adjusting the burner pressure (fig. 20, 21 and 22)
Reconnect the gas supply to the heater and open the
new gas pipe.
On the gas control block is point of pressure
measurement where the burner pressure can easily be
measured with a manometer. Loosen the screw at the
point of pressure measurement (20) and connect the
manometer.
Remove the cover of the gas control block by removing
the screw (21).To convert the appliance to propane or
natural gas the burner pressure must be adjusted with
the pressure regulating screw (22) as specified in the
table. Replace the cover.
Ignite the pilot light. Set the thermostat to the highest
setting and adjust the burner pressure as specified in the
table. Check the gas tightness! Turn the burner off again,
remove the manometer and tighten the screw at the
point of pressure measurement.

GENERAL NOTES

Gas Safety Regulations (for installation & use) 1998
In your own interest and that of safety, it is law that
all gas appliances are installed by competent
persons in accordance with the above regulations.
Failure to install appliances correctly could lead to
prosecution.
NB: The Council of Registered Gas Installers, whose
members are identified by the emblem shown here, are all
required to work to the recognised standards.

Cleaning and Maintenance

The appliance should be inspected once a year by a
qualified company, and cleaned and/or repaired as
necessary.The inspection and maintenance must at least
ensure that the appliance is working correctly and safely.
This can be done by your own gasinstaller or a specialised
maintenance company. It is advisable to remove any dust
from the appliance several times before and during the
heating season. After a while a deposit will form on the
inside of the glass pane.This can be removed with a damp
cloth or with a non-abrasive cleaning agent (e.g. brass
polish). Do this as soon as any deposit appears, to prevent
it from burning and becoming impossible to clean. Do not
use corrosive or abrasive substances to clean the casing.
Any damage to the coating, caused by things put on or
against the casing for example, is not covered by the
guarantee.
The chimney should be inspected regularly, to check that
all flue gasses are discharged through the chimney.
Excessive accumulation of soot in the chimney should be
avoided.The soot that does form should be removed, only
ever when cold, with a brush or vacuum cleaner.The
ventilation should also be checked regularly, to make sure
there are no obstructions.
NB: When replacing the thermocouple, the coupling nut in
the gas control block should first be tightened by hand and
then tightened a quarter-turn with an open-ended spanner.

Discoloration of walls and ceiling

Brown discoloration is an annoying problem, which is
difficult to solve. It can be caused by dust burning as a
result of poor ventilation, for example, or by cigarette
smoke or candles.