Start-Up; Electrical Dangers; Initial Start-Up Of The 'Ecopro - Ecolab EcoPro-ES-00510X-PFC-00S-1S-S0 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 184

Electrical dangers

DANGER!
Electrical hazards are marked by the symbol opposite.
Work in these areas may only be carried out by trained personnel with the
appropriate authorisation.
7.1

Initial start-up of the 'EcoPro'

Fig. 16: EcoPro control elements ''
1
Rotary button for stroke adjustment
2
Locking mechanism for fixing the rotary button in place
3
LED - Alarm signal, colour: red flashing
4
LED - Dosing mode "low", colour: yellow
1.
Install the mounting plate and pump in the required location and installation scenario.
Ä Chapter 6.2 'Assembly variants' on page 31
2.
Make the hydraulic connections.
Ä Chapter 6.3.1 'Hydraulic installation' on page 34
3.
If necessary, make the electrical connections for signal inputs.
Ä Chapter 6.3.4 'Electrical Installation' on page 42
4.
Connect the mains plug (fitted at the factory) to the power supply.
5.
Switch on the pump with the 'ON/OFF button'
6.
Reset the viscosity by pressing the 'ON/OFF' and 'Test'
buttons simultaneously (for approximately 3 seconds).
ð The LED that corresponds to the selected viscosity briefly flashes green (Fig. 16).
7.
Switch on the pump by pressing the 'ON/OFF button'
ð The pump resumes operation and the LED for the new viscosity setting flashes
(Fig. 16).
8.
Perform calibration on initial start-up:
Ä Chapter 7.4 'Calibration on initial start-up' on page 48
The enabled viscosity (high or low) is indicated by an LED display when the
pump is switched on.
Meaning of the LED colours:
n
LED - Metering mode "low" (left):
Permanently on when the pump is started, colour: green (standby).
Flashing when operated in "low" metering mode, colour: yellow.
n
LED - Metering mode "high" (right):
Flashing when operated in "high" metering mode, colour: yellow.
5
6
7
8
45
LED - When the pump is started: green (standby)
LED - Dosing mode "high", colour: flashing yellow
'ON/OFF button'
Test button
Cable bushing for the mains connection cable
.
.
417102264 Rev. 5-01.2019

Start-up