battioni Pagani GARDA EVO Serie Notice D'emploi Et D'entretien page 99

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

When carrying out maintenance operations, inspections, checks or repairs it is advisable to wear
the individual protective devices listed in this manual.
All maintenance operations, inspections, checks and repairs should be carried out with the greatest care and
with the power take-off disconnected.
The combined groups must be assembled and installed using the following procedure:
1) Install the GARDA EVO groups horizontally with the feet facing downwards. The assembly position on the vehicle
should be easy to access and be protected. There must be sufficient space for the suction and discharge lines. A 5°
maximum longitudinal slope of the GARDA EVO group with respect to the horizontal plane must not be exceeded.
2) Bolt the gearbox of the group by means of the screws and nuts through the holes provided in the feet of the
GARDA EVO gearbox.
3) The centrifugal pump, connected to the gearbox, does not feature support means;
4) Connect the centrifuge pump to the tank via a flexible coupling connection;
5) Connect the centrifuge pump to the swivel jet via a metal pipe of 3" or 4" gas, on which must be fitted a flexible
connection joint and a gate valve that must be closed during filling of the tank-car;
6) The high pressure pump connected to the gearbox must be supported and secured to the support plate of the
GARDA EVO group, as indicated in the instruction manual of the pump.
7) The rotary blades vacuum pump only needs to be supported by a metal sheet of suitable thickness and a layer of
rubber between the metal sheet and the feet of the same rotary blades vacuum pump to prevent breakage due to
vibrations of the Group. Do not fix the rotary blades vacuum pump with screws to the support plate.
8) Connect the suction/compression tube of the tank to the rotary blades vacuum pump as described in the
"Instructions manual for use and maintenance" of the individual pumps.
9) Connect the drive shaft of the tractor to the PTO of the GARDA EVO group for version D.
10) Connect the hydraulic pump to the hydraulic motor of the GARDA EVO
11) Connect the drive pulley belts to the driven pulley of the GARDA EVO group for version P.
The maximum permissible angle of the drive shaft is 15°. For no reason must
this inclination be exceeded.
The centrifugal pump, when being installed on a machine, must be equipped with protective devices
to isolate the moving parts and to prevent the operators from accessing.
When operating the centrifuge pump, the high pressure pump and the rotary blades vacuum pump, it is
necessary to use the individual means of protection prescribed by the Manufacturer of the machine on which
the pump itself is installed.
for use and maintenance of the combined groups for the GARDA EVO series
5 - ASSEMBLY, FITTING, INSTALLATION
Instruction manual
for version H.
group
page 81

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Garda evo dGarda evo pGarda evo h

Table des Matières