DESCRIPTION AND CHARACTERISTICS
Garda Evo is a combined group consisting of a gearbox that allows the activation of two outputs (blade pumps, blowers,
centrifugal pumps, high pressure pumps and PTO) alternate or simultaneously, from a single PTO. This information
relating to initial start applies to the Garda Evo, consisting of gearbox, hydraulic drive, centrifugal pump (output A) and
Aida blower (output B).
Parameters
HYDRAULIC MOT. RPM *
RPM OUTPUT A
RPM OUTPUT B
BLOWER PRESSURE
BLOWER VACUUM
*The input speed affects the speed in output A/B.
page 82
6 - INSTRUCTIONS FOR FIRST START-UP
Garda Evo lubricating oil and Aida blower multiplier
Aida blower rear tank lubricating oil
ISO VG 220 synthetic
Oil change 300 hours /12 months
Work parameters:
[rpm]
850 ÷ 900
[rpm]
-
[rpm]
-
[bar]
0,5 ÷ 1
[bar]
-0.5 ÷ -0.8
ISOVG460
8.7÷9 litres
0.7 litres
Max Parameters
1000
2388
3000
1.5
-0.9