battioni Pagani GARDA EVO Serie Notice D'emploi Et D'entretien page 110

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

instruction manual
for use and maintenance of the combined groups for the GARDA EVO series
GARDA EVO CENTR/D C6500/W
DESCRIPTION AND CHARACTERISTICS
Garda Evo is a combined group consisting of a gearbox that allows the activation of two outputs (blade pumps, blowers,
centrifugal pumps, high pressure pumps and PTO) alternate or simultaneously, from a single PTO. This initial start
information applies to Garda Evo centr.-D-W, consisting of gearbox, PTO drive and centrifuge pump (output A) and
rotary blade vacuum pumps (MEC II / BALLAST / KTS etc.) (output B).
Parameters
RPM PTO *
ROTARY BLADES VACUUM PUMP PRESSURE
ROTARY BLADES VACUUM PUMP
CENTRIFUGAL PUMP
*The input speed affects the speed in output A/B.
page 92
6.3 - INSTRUCTIONS FOR FIRST START-UP
Lubrication oil rotary blades vacuum pumps
Lubricating oil Garda Evo
Oil change 300 hours /12 months
Work parameters:
[rpm]
850 ÷ 900
[bar]
0.5 ÷ 1
[bar]
-0.5 ÷ -0.8
[rpm]
*
ISO VG 100
ISO VG 460
3.8÷4.2 litres
Max Parameters
1000
1.5
-0.95
2390

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Garda evo dGarda evo pGarda evo h

Table des Matières