On-Off Functions); Technical Characteristics - Nice ROBUS RB400 Instructions Et Avertissements Pour L'installation Et L'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 55

8) Technical characteristics

Nice S.p.a., in order to improve its products, reserves the right to modify their technical characteristics at any time without prior notice. In
any case, the manufacturer guarantees their functionality and fitness for the intended purposes.
All the technical characteristics refer to an ambient temperature of 20°C (±5°C)
Technical characteristics ROBUS
Model type
Type
Pinion
Maximum frequency of ope-
rating cycles (nominal torque)
Maximum continuous opera-
ting time (nominal torque)
Application limits
Durability
Power input
Thrust maximum absorbed
power [equivalent to amperes]
Insulation class
Emergency power supply
Flasher output
Open Gate Indicator Output
BLUEBUS output
STOP input
Step-by-step Input
OPEN input
CLOSE input
Radio connector
Radio AERIAL Input
Programmable functions
Self-Recognition functions
Use in acid, saline or poten-
tially explosive atmosphere
RB400
RB600 / RB600P
Electromechanical gearmotor for the automatic movement of sliding gates for residential use, com-
plete with electronic control unit
Z15m4
Z15m4
80 cycles per day
100 cycles per
(the control unit
day (the control
allows up to the
unit allows up
maximum descri-
to the maximum
bed in table 2)
described in table
2)
7 minutes
7 minutes
(the control unit
(the control unit
allows up to the
allows up to the
maximum descri-
maximum descri-
bed in table 2)
bed in table 2)
ROBUS is generally able to automate gates up to the weight and length limits given in table 2
Estimated between 20,000 and 250,000 cycles, depending on the conditions given in Table 2
330W [2A]
515W [2.5A]
[3.9A version /V1]
[4.8A version /V1]
1 (a safety grounding system is required)
With PS124 optional accessory
For 2 LUCYB flashing lights (12V, 21 W lamp)
For one 24V maximum 4W bulb (the output voltage may vary between –30 and +50% and can also
control small relays)
One output with a maximum load of 15 BLUEBUS units
For normally closed or normally open contacts, for 8.2 kΩ constant resistance; with self-recognition
(any variation from the memorized status causes the "STOP" command)
For normally open contacts (the closing of the contact causes the "STEP-BY-STEP" command)
For normally open contacts (the closing of the contact causes the "OPEN" command)
For normally open contacts (the closing of the contact causes the "CLOSE" command)
"SM" connector for SMXI and SMXIS receivers
52Ω for RG58 or similar type of cable
8 ON-OFF functions and 8 adjustable functions (see tables 5 and 7)
Automatic identification of devices connected with the BLUEBUS outlet
Self-recognition of the type of "STOP" device (Normally Open, Normally Closed contact or 8.2 kΩ
fixed resistor)
Self-recognition of the gate length and calculation of the deceleration points and the partial opening
point.
No
No
RB1000 / RB1000P
Z15m4
150 cycles per day
80 cycles per
(the control unit
day (the control
allows up to the
unit allows up
maximum described
to the maximum
in table 2)
described in
table 2)
5 minutes
6 minutes
(the control unit
(the control unit
allows up to the
allows up to
maximum described
the maximum
in table 2)
described in
table 2)
230Vac (+10% -15%) 50/60Hz.
450W [2.3A]
[4.4A version /V1]
[3.9A version /V1]
No
RB250HS
RB500HS
Z15m4
Z18m4
100 cycles per
day (the control
unit allows up
to the maximum
described in
table 2)
6 minutes
(the control unit
allows up to
the maximum
described in
table 2)
330W [2A]
330W [2.5A]
[4.8A version /V1]
No
No
English – 23

Publicité

Table des Matières
loading

Table des Matières