Configuration & Data" Menu; Configuration Menu Item; Data Menu Item; Messages Menu Item - Garant TWdrive Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Menu overview
 N m
 in lb
 ft lb
DE
Preload (M
)
P
Target angle (α)
 No tolerance specification
 Relative tolerance specification
 Absolute tolerance specification
 Upper angle tolerance limit UT (α
EN
 Lower angle tolerance limit LT (α
Target torque (STOP) M
 No tolerance specification
 Relative tolerance specification
 Absolute tolerance specification
 Upper torque tolerance limit UT (M
FR
 Lower torque tolerance limit LT (M
 Peak (P)
 Track (T)
Extension length
Summarisation
IT
ES
32
32
The desired torque unit is defined here.
The preload value is defined here.
The target angle value is defined here.
Whether a tolerance range is assigned to the value is defined
here. The tolerances may be specified relative to the value as
a percentage. An absolute tolerance specification with
concrete values is also possible.
The angle tolerance range is defined here.
)
UT
If no tolerance specification has been selected, this menu item
)
LT
is not displayed.
The target torque value is defined here.
Whether a tolerance range is assigned to the value is defined
here. The tolerances may be specified relative to the value as
a percentage. An absolute tolerance specification with
concrete values is also possible.
The torque tolerance range is defined here.
)
UT
If no tolerance specification has been selected, this menu item
)
LT
is not displayed.
The function mode is selected here. See page 14.
The extension length for the installed plug-in tool is input here.
A summarisation of the settings which have been made is
displayed here. The summarisation can be confirmed with OK
or the bolting process may be commenced. The
summarisation is automatically hidden.
Menu overview
"Configuration & Data" menu
The "Configuration & Data" menu contains the following menu items:
 Configuration
 Data
 Messages
 Version Info.

Configuration menu item

Alert
The alert limit is defined by inputting a value. If the alert limit is
reached, the yellow signal lamps light up and the value is
shown in yellow on the display.
The alert is a percentage value referring to the lower tolerance
limit. If the lower tolerance limit is zero, this value refers to the
target value.
Vibration on/off
Here, you define whether the vibration signal is to be switched
on or not on the torque and angle wrench.
Save on/off
Whether bolting process data are to be saved or not is defined
here.
Ser. Communication
This menu item must be activated for calibration with a
STAHLWILLE perfectControl
facility.
So that the torque and angle wrench functions flawlessly
again, the torque and angle wrench must be switched off once
after calibration.
Calibration Info
The next due calibration date is displayed here.
The torque and angle wrench cycles which have taken place
up to the current point in time are also displayed.
Max. Loads
The four highest applied torques are displayed here.

Data menu item

Saved Fastener Data
The saved fastener data can be seen here.

Messages menu item

Existing Messages
Existing messages, e.g. that the calibration date has been
exceeded, can be seen here.