Function Modes; Technical Data - Garant TWdrive Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Description
Angle
In this measuring mode, bolting is only implemented
according to the angle. Angle measurement begins
DE
after exceeding the preload. The torque and angle
wrench evaluates the angle and responds with
corresponding signals:
 Signal lamps
 Audible signal
 Colour representation of the display value
 Vibration
For this to occur, you must have input the specified
values into the torque and angle wrench.
EN
Torque-angle
In this measuring mode, the torque and angle are
evaluated. To obtain a positive bolting operation
evaluation, both values must lie within the defined
tolerance range. The stop signal is triggered on
reaching the target torque. Angle measurement
begins after exceeding the preload.
The torque and angle wrench responds with
corresponding signals:
FR
 Signal lamps
 Audible signal
 Colour representation of the display value
 Vibration
For this to occur, you must have input the specified
values into the torque and angle wrench.
IT
ES
14
14
Angle-torque
In this measuring mode, the torque and angle are
evaluated. To obtain a positive bolting operation
evaluation, both values must lie within the defined
tolerance range. The stop signal is triggered on
reaching the target angle. Angle measurement
begins after exceeding the preload.
The torque and angle wrench responds with
corresponding signals:
 Signal lamps
 Audible signal
 Colour representation of the display value
 Vibration
For this to occur, you must have input the specified
values into the torque and angle wrench.

Function modes

The desired function mode must be assigned in
each of the four measuring modes.
The following function modes are available:
 Peak (P)
 Track (T)
This is queried each time whilst a bolting operation
is being configured.
Peak
During a bolting process, the maximum torque or
the maximum angle is measured and shown on the
display. This is the so-called peak.
In this function mode, the values are not saved
automatically after a bolting process. You may
still save the values. To do this, press OK once
after tightening.
Track
In this function mode, the currently present
torque/angle is measured and shown on the
display.
Description
In this function mode, the values are not saved
automatically after a bolting process. You may
still save the values. To do this, press OK twice
after tightening.

Technical data

655250
Garant/30
Garant/120
Square insert [mm]
9×12
14×18
Function length
242.5
461
[mm]
Length [mm]
277
476
Width [mm]
50
50
Height [mm]
41.5
41.5
Weight [g]
487
952
1
1
Without plug-in tool and batteries
www.hoffmann-group.com
Garant/200
Garant/400
14×18
14×18
559.5
784.5
575
800
50
50
41.5
41.5
1170
1807
15
DE
DE
EN
FR
FR
IT
IT
ES
ES
15

Publicité