Angle-Torque Measuring Mode - Garant TWdrive Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Menu overview
 N m
 in lb
 ft lb
DE
Preload (M
)
P
Target angle (α)
 No tolerance specification
 Relative tolerance specification
 Absolute tolerance specification
 Upper angle tolerance limit UT (α
EN
 Lower angle tolerance limit LT (α
Target torque (STOP) M
 No tolerance specification
 Relative tolerance specification
 Absolute tolerance specification
 Upper torque tolerance limit UT (M
FR
 Lower torque tolerance limit LT (M
 Peak (P)
 Track (T)
Extension length
Summarisation
IT
ES
30
30
The desired torque unit is defined here.
The preload value is defined here.
The target angle value is defined here.
Whether a tolerance range is assigned to the value is defined
here. The tolerances may be specified relative to the value as
a percentage. An absolute tolerance specification with
concrete values is also possible.
The angle tolerance range is defined here.
)
UT
If no tolerance specification has been selected, this menu item
)
LT
is not displayed.
The target torque value is defined here.
Whether a tolerance range is assigned to the value is defined
here. The tolerances may be specified relative to the value as
a percentage. An absolute tolerance specification with
concrete values is also possible.
The torque tolerance range is defined here.
)
UT
If no tolerance specification has been selected, this menu item
)
LT
is not displayed.
The function mode is selected here. See page 14.
The extension length for the installed plug-in tool is input here.
A summarisation of the settings which have been made is
displayed here. The summarisation can be confirmed with OK
or the bolting process may be commenced. The
summarisation is automatically hidden.
Menu overview

Angle-torque measuring mode

www.hoffmann-group.com
DE
DE
EN
FR
FR
IT
IT
ES
ES
31
31

Publicité

Table des Matières
loading

Table des Matières