Angle Measuring Mode - Garant TWdrive Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Menu overview
 N m
 in lb
 ft lb
DE
Target torque (STOP) M
 No tolerance specification
 Relative tolerance specification
 Absolute tolerance specification
 Upper torque tolerance limit UT (M
 Lower torque tolerance limit LT (M
EN
 Peak (P)
 Track (T)
Extension length
Summarisation
FR
IT
ES
26
26
The desired torque unit is defined here.
The target torque value is defined here.
Whether a tolerance range is assigned to the value is defined
here. The tolerances may be specified relative to the value as
a percentage. An absolute tolerance specification with
concrete values is also possible.
The torque tolerance range is defined here.
)
UT
If no tolerance specification has been selected, this menu item
)
LT
is not displayed.
The function mode is selected here. See page 14.
The extension length for the installed plug-in tool is input here.
A summarisation of the settings which have been made is
displayed here. The summarisation can be confirmed with OK
or the bolting process may be commenced. The
summarisation is automatically hidden.