Mounting; Preparation For Mounting; Electrical Connections - Assa Abloy effeff 809-12 Notice D'installation Et De Montage

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

!
!
!
Prepare
and clean
the lock pocket
A
Connect the cable
EN
50

Mounting

Warning!
Life-threatening danger due to electric shock: Improper wiring is life-threatening and can destroy the
electric security lock 809. The connection of the power supply may only be carried out by trained, qualified
personnel.
Caution!
Risk of injury due to sharp edges and chippings: There is a risk of injury from sharp edges resulting from
drilling and other cutting work. Be sure to protect your eyes with suitable protective goggles. Have the
work performed by appropriately trained, qualified personnel.

Preparation for mounting

Caution!
Unsuitable doors diminish personal safety and intrusion protection: Only approved and technically
faultless doors are suitable for the mounting of the electric security lock 809. Prior to the mounting of the
electric security lock 809, the door must be inspected to ensure that it closes properly and is not warped.
The door must be approved for the use of the electric security lock 809.
1
Finish the lock pocket in a suitable vertical mounting position in the door leaf. Take into account an
additional 30 mm for the cable loop for the depth.
2
Finish the drilled holes for the fixing screws for tubular frame doors according to Pic. 13.
3
Drill the holes for the lock escutcheons.
4
Clean the lock pocket and all drilled holes by blowing them out or vacuuming.
9 The locket is prepared for the further mounting.

Electrical connections

Impor tant!
A faulty connection will destroy the lock or impair its function: When connecting the cable, the
contacts may not be reversed, otherwise the lock can be destroyed or not function properly. Observe the
numbering and colour coding according to the connection diagrams.
1
Prepare the wiring for the electric security lock 809 ("Electrical connection", page 52).
2
Connect the cable for the power supply and control according to Pic. 8.
9 The lock is now electrically connected.
Installation

Publicité

Table des Matières
loading

Table des Matières